Electrical
An extensive range of robust fittings and weatherproof products.
Squeeze connectors are used to terminate AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure.
Model Number |
---|
SSQ037I |
SSQ050I |
SSQ075I |
SSQ100I |
SSQ125I |
SSQ150I |
SSQ200I |
SSQ250I |
SSQ300I |
SSQ350I |
SSQ400I |
A | B | C |
---|---|---|
1.08 | 0.49 | 0.62 |
A | B | C |
---|---|---|
1.58 | 0.58 | 0.99 |
A | B | C |
---|---|---|
1.68 | 0.58 | 1.18 |
Squeeze connectors are used to terminate AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure.
Model Number |
---|
SSQ037 |
SSQ050 |
SSQ075 |
SSQ100 |
SSQ125 |
SSQ150 |
SSQ150U |
SSQ200 |
SSQ200U |
SSQ250 |
SSQ300 |
SSQ350 |
SSQ350U |
SSQ400 |
A | B | C |
---|---|---|
1 | 0.41 | 0.62 |
A | B | C |
---|---|---|
1.5 | 0.5 | 0.99 |
A | B | C |
---|---|---|
1.59 | 0.5 | 1.18 |
A | B | C |
---|---|---|
1.75 | 0.55 | 1.44 |
A | B | C |
---|---|---|
1.9 | 0.61 | 1.76 |
A | B | C |
---|---|---|
2.03 | 0.61 | 2.06 |
A | B | C |
---|---|---|
2.1 | 0.61 | 2.55 |
Screw-in type couplings are used to join two lengths of FMC where minimum spacing between conduit is desired. For dry location applications.
Model Number |
---|
SICP050 |
SICP075 |
SICP100 |
SICP125 |
SICP150 |
SICP200 |
A | B | C |
---|---|---|
1.79 | 0.92 | 0.2 |
A | B | C |
---|---|---|
2.11 | 1.13 | 0.22 |
A | B | C |
---|---|---|
2.42 | 1.36 | 0.31 |
A | B | C |
---|---|---|
2.76 | 1.75 | 0.31 |
A | B | C |
---|---|---|
3.07 | 2.11 | 0.31 |
A | B | C |
---|---|---|
3.28 | 2.67 | 0.31 |
Snap Lock® screw-in type connectors are used to terminate FMC/RWFMC to a knockout in a dry location box or enclosure.
Model Number |
---|
SICN037S |
SICN050S |
A | B | C |
---|---|---|
1.19 | 0.83 | 0.4 |
A | B | C |
---|---|---|
1.27 | 0.83 | 0.4 |
Screw-in type connectors are used to terminate FMC to a knockout in a dry location box or enclosure.
Model Number |
---|
SICN037I |
SICN050I |
SICN075I |
SICN100I |
SICN125I |
SICN150I |
SICN200I |
A | B | C |
---|---|---|
1.36 | 0.92 | 0.46 |
Screw-in type connectors are used to terminate FMC to a knockout in a dry location box or enclosure.
Model Number |
---|
SICN037 |
SICN050 |
SICN075 |
SICN100 |
SICN125 |
SICN150 |
SICN200 |
A | B | C |
---|---|---|
1.28 | 0.92 | 0.46 |
A | B | C |
---|---|---|
1.35 | 0.92 | 0.41 |
A | B | C |
---|---|---|
1.61 | 1.13 | 0.39 |
A | B | C |
---|---|---|
1.93 | 1.36 | 0.54 |
A | B | C |
---|---|---|
2.13 | 1.75 | 0.61 |
A | B | C |
---|---|---|
2.32 | 2.11 | 0.63 |
A | B | C |
---|---|---|
2.56 | 2.67 | 0.76 |
Used to terminate flexible metal conduit, armored or metal clad cables to an enclosure or outlet box
Model Number |
---|
SC050 |
Snap Lock® saddle connectors are used to terminate NM, AC or MC to a knockout in a dry location box or enclosure.
Model Number |
---|
SAD037S |
A | B | C |
---|---|---|
1.65 | 1.04 | 0.93 |
Saddle connectors are used to terminate NM, AC or MC to a knockout in a dry location box or enclosure.
Model Number |
---|
SAD037 |
A | B | C |
---|---|---|
0.9 | 1.61 | 0.9 |
Used to terminate non-metallic, armored or metal clad cables to an enclosure or outlet box
Model Number |
---|
SAD037DC |
SAD050DC |
SAD075DC |
SAD100DC |
Used to terminate flexible metal conduit, armored or metal clad cables to an enclosure or outlet box
Model Number |
---|
MSSQ037I |
MSSQ050I |
MSSQ075I |
MSSQ100I |
MSSQ125I |
MSSQ150I |
MSSQ200I |
MSSQ250I |
MSSQ300I |
MSSQ350I |
MSSQ400I |
Used to terminate flexible metal conduit, armored or metal clad cables to an enclosure or outlet box
Model Number |
---|
MSSQ037 |
MSSQ050 |
MSSQ075 |
MSSQ100 |
MSSQ125 |
MSSQ150 |
MSSQ200 |
MSSQ250 |
MSSQ300 |
MSSQ350 |
MSSQ400 |
Used to terminate flexible metal conduit, armored or metal clad cables to an enclosure or outlet box
Used to terminate flexible metal conduit, armored or metal clad cables to an enclosure or outlet box
Model Number |
---|
MASQ037I |
MASQ050I |
MASQ075I |
MASQ100I |
MASQ125I |
MASQ150I |
MASQ200I |
MASQ250I |
MASQ300I |
MASQ350I |
MASQ400I |
Used to terminate flexible metal conduit, armored or metal clad cables to an enclosure or outlet box
Model Number |
---|
MASQ037 |
MASQ050 |
MASQ075 |
MASQ100 |
MASQ125 |
MASQ150 |
MASQ200 |
MASQ250 |
MASQ300 |
MASQ350 |
MASQ400 |
Set screw flex connectors are used to terminate FMC/RWFMC to a knockout in a dry location box or enclosure.
Model Number |
---|
FCA050I |
FCA075I |
A | B | C |
---|---|---|
0.96 | 1.55 | 0.4 |
Combination connectors are used to terminate AC, MC or FMC to a knockout in a dry location box or enclosure.
Model Number |
---|
FBMC037 |
A | B | C |
---|---|---|
0.74 | 1.16 | 0.36 |
Set screw flex connectors are used to terminate FMC/RWFMC to a knockout in a dry location box or enclosure.
Model Number |
---|
FCA050 |
FCA075 |
A | B | C |
---|---|---|
0.96 | 1.48 | 0.4 |
A | B | C |
---|---|---|
1.15 | 1.55 | 0.49 |
Double Snap Lock® duplex connectors are used to terminate two runs of AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure. The patented Double Snap Lock® design provides a faster installation.
Snap Lock® duplex connectors are used to terminate two runs of AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure.
Model Number |
---|
DUP1S |
A | B | C |
---|---|---|
1.64 | 1.45 | 0.41 |
Double Snap Lock® duplex connectors are used to terminate two runs of AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure. The patented Double Snap Lock® design provides a faster installation.
Model Number |
---|
DUP1DSI |
A | B | C |
---|---|---|
2.1 | 1.49 | 0.4 |
Used to terminate flexible metal conduit, armored or metal clad cables to an enclosure
Model Number |
---|
DUP2 |
Duplex connectors are used to terminate two runs of AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure.
Model Number |
---|
DUP1 |
A | B | C |
---|---|---|
1.6 | 1.49 | 0.42 |
Combination couplings are used to provide a transition from steel EMT conduit to Flexible Metal Conduit. For dry location applications.
Model Number |
---|
CSICP050 |
CSICP075 |
CSICP100 |
A | B | C |
---|---|---|
1.4 | 0.98 | 0.15 |
A | B | C |
---|---|---|
1.52 | 1.23 | 0.21 |
A | B | C |
---|---|---|
1.99 | 1.52 | 0.31 |
Combination couplings are used to provide a transition from steel EMT conduit to Flexible Metal Conduit. For dry location applications.
Model Number |
---|
CMB050SS |
CMB075SS |
A | B | C |
---|---|---|
0.72 | 0.93 | 1.53 |
A | B | C |
---|---|---|
0.93 | 1.16 | 1.91 |
Used to terminate armored or metal clad cable to an enclosure or outlet box
Model Number |
---|
CBXC037DSI |
One-hole flex straps are used to provide support for runs of AC or MC as required by the National Electric Code (NEC).
Model Number |
---|
BXS037 |
A | B | C |
---|---|---|
1.12 | 0.5 | 0.53 |
Double Snap Lock® AC/MC connectors are used to terminate AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure. The patented Double Snap Lock® design provides a faster installation.
Model Number |
---|
BXCS037DSI |
AC/MC connectors are used to terminate AC or MC to a knockout in a dry location box or enclosure.
Model Number |
---|
BXC037S |
A | B | C |
---|---|---|
0.87 | 0.94 | 0.4 |
Double Snap Lock® AC/MC connectors are used to terminate AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure. The patented Double Snap Lock® design provides a faster installation.
Model Number |
---|
BXC037DSI |
A | B | C |
---|---|---|
1.45 | 0.76 | 0.39 |
AC/MC connectors are used to terminate AC or MC to a knockout in a dry location box or enclosure.
Model Number |
---|
BXC037 |
A | B | C |
---|---|---|
0.79 | 0.63 | 0.37 |
Double Snap Lock® 90° squeeze connectors are used to terminate AC, MC or FMC/RWFMC to a knockout in a metal box or enclosure where a 90° bend is required. The patented Double Snap Lock® design provides a faster installation. For dry location applications.
Model Number |
---|
ASQ037DSI |
ASQ050DSI |
A | B | C |
---|---|---|
1.37 | 1.73 | 0 |
A | B | C |
---|---|---|
1.68 | 2.06 | 0 |
90° squeeze connectors are used to terminate AC, MC or FMC/RWFMC to a knockout in a metal box or enclosure where a 90° bend is required. For dry location applications.
Model Number |
---|
ASQ037I |
ASQ050I |
ASQ075I |
ASQ100I |
ASQ125I |
ASQ150I |
ASQ200I |
ASQ250I |
ASQ300I |
ASQ350I |
ASQ400I |
A | B | C |
---|---|---|
1.18 | 1.3 | 0.46 |
A | B | C |
---|---|---|
1.51 | 1.63 | 0.51 |
A | B | C |
---|---|---|
1.65 | 1.89 | 0.51 |
90° squeeze connectors are used to terminate AC, MC or FMC/RWFMC to a knockout in a metal box or enclosure where a 90° bend is required. For dry location applications.
Model Number |
---|
ASQ037 |
ASQ050 |
ASQ075 |
ASQ100 |
ASQ125 |
ASQ150 |
ASQ200 |
ASQ250 |
ASQ300 |
ASQ350 |
ASQ400 |
A | B | C |
---|---|---|
1.18 | 1.29 | 0.39 |
A | B | C |
---|---|---|
1.51 | 1.63 | 0.44 |
A | B | C |
---|---|---|
1.65 | 1.89 | 0.43 |
A | B | C |
---|---|---|
2.13 | 2.3 | 0.53 |
A | B | C |
---|---|---|
3.01 | 2.7 | 0.59 |
A | B | C |
---|---|---|
4.8 | 3.59 | 0.71 |
A | B | C |
---|---|---|
4.8 | 3.59 | 0.71 |
Snap-in connectors are used to terminate AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure.
Model Number |
---|
AMC050 |
AMC075 |
A | B | C |
---|---|---|
1.33 | 0.98 | 1.72 |
A | B | C |
---|---|---|
1.65 | 1.34 | 2.02 |
Duplex snap-in connectors are used to terminate two runs of AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure.
Model Number |
---|
AMC052 |
A | B | C |
---|---|---|
1.66 | 1.76 | 0.89 |
Squeeze connectors are used to terminate AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
69401 | 1 | 30 | Polybag |
69407 | 1 | 25 | Polybag |
69408 | 1 | 25 | Polybag |
A | B | C |
---|---|---|
1.08 | 0.49 | 0.62 |
A | B | C |
---|---|---|
1.58 | 0.58 | 0.99 |
A | B | C |
---|---|---|
1.68 | 0.58 | 1.18 |
Squeeze connectors are used to terminate AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
49401 | 1 | 30 | Polybag |
55401M | 50 | 1 | Contractor Pack |
49407 | 1 | 25 | Polybag |
44407 | 3 | 20 | Polybag |
SC-50 | 25 | 2 | Contractor Pack |
49408 | 1 | 25 | Polybag |
44408 | 3 | 20 | Polybag |
55408M | 25 | 2 | Contractor Pack |
02-55410 | 1 | 10 | Boxed - Individual UPC |
02-55412 | 1 | 10 | Boxed - Individual UPC |
02-55414 | 1 | 10 | Boxed - Individual UPC |
02-55416 | 1 | 10 | Boxed - Individual UPC |
A | B | C |
---|---|---|
1 | 0.41 | 0.62 |
A | B | C |
---|---|---|
1.5 | 0.5 | 0.99 |
A | B | C |
---|---|---|
1.59 | 0.5 | 1.18 |
A | B | C |
---|---|---|
1.75 | 0.55 | 1.44 |
A | B | C |
---|---|---|
1.9 | 0.61 | 1.76 |
A | B | C |
---|---|---|
2.03 | 0.61 | 2.06 |
A | B | C |
---|---|---|
2.1 | 0.61 | 2.55 |
Screw-in type couplings are used to join two lengths of FMC where minimum spacing between conduit is desired. For dry location applications.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
18127 | 1 | 10 | Polybag |
49013 | 1 | 20 | Polybag |
56013 | 50 | 10 | Bulk - No individual UPC |
18128 | 1 | 10 | Polybag |
49014 | 1 | 25 | Polybag |
44014 | 5 | 20 | Polybag |
56014 | 25 | 10 | Bulk - No individual UPC |
02-56015 | 1 | 10 | Boxed - Individual UPC |
02-56016 | 1 | 10 | Boxed - Individual UPC |
02-56017 | 1 | 10 | Boxed - Individual UPC |
02-56018 | 1 | 10 | Boxed - Individual UPC |
A | B | C |
---|---|---|
1.79 | 0.92 | 0.2 |
A | B | C |
---|---|---|
2.11 | 1.13 | 0.22 |
A | B | C |
---|---|---|
2.42 | 1.36 | 0.31 |
A | B | C |
---|---|---|
2.76 | 1.75 | 0.31 |
A | B | C |
---|---|---|
3.07 | 2.11 | 0.31 |
A | B | C |
---|---|---|
3.28 | 2.67 | 0.31 |
Screw-in type connectors are used to terminate FMC to a knockout in a dry location box or enclosure.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
69335 | 1 | 50 | Polybag |
A | B | C |
---|---|---|
1.36 | 0.92 | 0.46 |
Screw-in type connectors are used to terminate FMC to a knockout in a dry location box or enclosure.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
49009 | 1 | 50 | Polybag |
42009 | 2 | 25 | Polybag |
18129 | 4 | 10 | Polybag |
56009 | 50 | 10 | Bulk - No individual UPC |
GC-38 | 50 | 2 | Contractor Pack |
49010 | 1 | 50 | Polybag |
18130 | 4 | 10 | Polybag |
44010 | 5 | 20 | Polybag |
56010 | 50 | 10 | Bulk - No individual UPC |
GC-50 | 50 | 2 | Contractor Pack |
49011 | 1 | 20 | Polybag |
18131 | 2 | 5 | Polybag |
56011 | 25 | 10 | Bulk - No individual UPC |
GC-75 | 25 | 2 | Contractor Pack |
02-56012 | 1 | 10 | Boxed - Individual UPC |
02-57013 | 1 | 10 | Boxed - Individual UPC |
02-57014 | 1 | 10 | Boxed - Individual UPC |
02-57015 | 1 | 10 | Boxed - Individual UPC |
A | B | C |
---|---|---|
1.28 | 0.92 | 0.46 |
A | B | C |
---|---|---|
1.35 | 0.92 | 0.41 |
A | B | C |
---|---|---|
1.61 | 1.13 | 0.39 |
A | B | C |
---|---|---|
1.93 | 1.36 | 0.54 |
A | B | C |
---|---|---|
2.13 | 1.75 | 0.61 |
A | B | C |
---|---|---|
2.32 | 2.11 | 0.63 |
A | B | C |
---|---|---|
2.56 | 2.67 | 0.76 |
Snap Lock® screw-in type connectors are used to terminate FMC/RWFMC to a knockout in a dry location box or enclosure.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
49170 | 1 | 25 | Polybag |
42170 | 2 | 20 | Polybag |
GC-138 | 25 | 2 | Contractor Pack |
49171 | 1 | 25 | Polybag |
A | B | C |
---|---|---|
1.19 | 0.83 | 0.4 |
A | B | C |
---|---|---|
1.18 | 1.3 | 0.39 |
A | B | C |
---|---|---|
1.27 | 0.83 | 0.4 |
Snap Lock® saddle connectors are used to terminate NM, AC or MC to a knockout in a dry location box or enclosure.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
49504 | 1 | 25 | Polybag |
A | B | C |
---|---|---|
1.65 | 1.04 | 0.93 |
Saddle connectors are used to terminate NM, AC or MC to a knockout in a dry location box or enclosure.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
49503 | 1 | 20 | Polybag |
44503 | 5 | 10 | Polybag |
55503 | 50 | 10 | Bulk - No individual UPC |
A | B | C |
---|---|---|
0.9 | 1.61 | 0.9 |
Set screw flex connectors are used to terminate FMC/RWFMC to a knockout in a dry location box or enclosure.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
69090 | 1 | 25 | Polybag |
A | B | C |
---|---|---|
0.96 | 1.55 | 0.4 |
Set screw flex connectors are used to terminate FMC/RWFMC to a knockout in a dry location box or enclosure.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
49090 | 1 | 12 | Polybag |
44090 | 3 | 20 | Polybag |
44091 | 3 | 5 | Polybag |
A | B | C |
---|---|---|
0.96 | 1.48 | 0.4 |
A | B | C |
---|---|---|
1.15 | 1.55 | 0.49 |
Combination connectors are used to terminate AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
42028 | 2 | 12 | Polybag |
A | B | C |
---|---|---|
0.77 | 0.91 | 0.39 |
Combination connectors are used to terminate AC, MC or FMC to a knockout in a dry location box or enclosure.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
49502 | 1 | 100 | Polybag |
44002 | 3 | 20 | Polybag |
42002 | 5 | 25 | Polybag |
C-510 | 100 | 2 | Contractor Pack |
A | B | C |
---|---|---|
0.74 | 1.16 | 0.36 |
Snap Lock® duplex connectors are used to terminate two runs of AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
49631 | 1 | 12 | Polybag |
A | B | C |
---|---|---|
1.64 | 1.45 | 0.41 |
Duplex connectors are used to terminate two runs of AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
18630 | 1 | 5 | Polybag |
49630 | 1 | 20 | Polybag |
A | B | C |
---|---|---|
1.6 | 1.49 | 0.42 |
Double Snap Lock® duplex connectors are used to terminate two runs of AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure. The patented Double Snap Lock® design provides a faster installation.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
49635 | 1 | 12 | Polybag |
A | B | C |
---|---|---|
2.1 | 1.49 | 0.4 |
Combination couplings are used to provide a transition from steel EMT conduit to Flexible Metal Conduit. For dry location applications.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
49289 | 1 | 15 | Polybag |
55289 | 50 | 10 | Bulk - No individual UPC |
49290 | 1 | 10 | Polybag |
55290 | 25 | 10 | Bulk - No individual UPC |
49291 | 1 | 5 | Polybag |
55291 | 25 | 10 | Bulk - No individual UPC |
A | B | C |
---|---|---|
1.4 | 0.98 | 0.15 |
A | B | C |
---|---|---|
1.52 | 1.23 | 0.21 |
A | B | C |
---|---|---|
1.99 | 1.52 | 0.31 |
Combination couplings are used to provide a transition from steel EMT conduit to Flexible Metal Conduit. For dry location applications.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
49280 | 1 | 15 | Polybag |
55280 | 25 | 10 | Polybag |
49281 | 1 | 10 | Polybag |
55281 | 25 | 10 | Polybag |
A | B | C |
---|---|---|
0.72 | 0.93 | 1.53 |
A | B | C |
---|---|---|
0.93 | 1.16 | 1.91 |
Double Snap Lock® cut-in connectors are used to terminate AC, MC or FMC/RWFMC to a knockout in an old work (cut-in) dry location box or enclosure. The Double Snap Lock® design provides a faster installation.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
45510 | 2 | 12 | Polybag |
A | B | C |
---|---|---|
1.54 | 1.11 | 1.1 |
One-hole flex straps are used to provide support for runs of AC or MC as required by the National Electric Code (NEC).
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
47919 | 3 | 50 | Polybag |
44919 | 10 | 20 | Polybag |
55919M | 100 | 2 | Contractor Pack |
55919 | 100 | 2 | Contractor Pack |
A | B | C |
---|---|---|
1.12 | 0.5 | 0.53 |
Double Snap Lock® AC/MC connectors are used to terminate AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure. The patented Double Snap Lock® design provides a faster installation.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
45065 | 2 | 12 | Polybag |
A | B | C |
---|---|---|
1.42 | 0.79 | 0.39 |
AC/MC connectors are used to terminate AC or MC to a knockout in a dry location box or enclosure.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
42502 | 5 | 10 | Polybag |
45502 | 2 | 12 | Polybag |
C-560 | 25 | 2 | Contractor Pack |
A | B | C |
---|---|---|
0.87 | 0.94 | 0.4 |
Double Snap Lock® AC/MC connectors are used to terminate AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure. The patented Double Snap Lock® design provides a faster installation.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
42505 | 5 | 10 | Polybag |
45505 | 2 | 12 | Polybag |
C-570 | 25 | 2 | Contractor Pack |
A | B | C |
---|---|---|
1.45 | 0.76 | 0.39 |
AC/MC connectors are used to terminate AC or MC to a knockout in a dry location box or enclosure.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
49501 | 1 | 100 | Polybag |
18058 | 4 | 10 | Polybag |
45501 | 10 | 15 | Polybag |
C-550 | 100 | 5 | Contractor Pack |
A | B | C |
---|---|---|
0.79 | 0.63 | 0.37 |
90° squeeze connectors are used to terminate AC, MC or FMC/RWFMC to a knockout in a metal box or enclosure where a 90° bend is required. For dry location applications.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
69801 | 1 | 50 | Polybag |
69804 | 1 | 20 | Polybag |
69806 | 1 | 20 | Polybag |
A | B | C |
---|---|---|
1.18 | 1.3 | 0.46 |
A | B | C |
---|---|---|
1.51 | 1.63 | 0.51 |
A | B | C |
---|---|---|
1.65 | 1.89 | 0.51 |
Double Snap Lock® 90° squeeze connectors are used to terminate AC, MC or FMC/RWFMC to a knockout in a metal box or enclosure where a 90° bend is required. The patented Double Snap Lock® design provides a faster installation. For dry location applications.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
49815 | 2 | 6 | Polybag |
49816 | 1 | 12 | Polybag |
A | B |
---|---|
1.37 | 1.73 |
A | B |
---|---|
1.68 | 2.06 |
90° squeeze connectors are used to terminate AC, MC or FMC/RWFMC to a knockout in a metal box or enclosure where a 90° bend is required. For dry location applications.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
49801 | 1 | 50 | Polybag |
44801 | 2 | 20 | Polybag |
55801M | 50 | 2 | Contractor Pack |
49804 | 1 | 20 | Polybag |
55804 | 25 | 10 | Polybag |
55804M | 25 | 2 | Contractor Pack |
49806 | 1 | 6 | Polybag |
55806 | 10 | 10 | Polybag |
02-55807 | 1 | 10 | Polybag |
02-55808 | 1 | 10 | Polybag |
02-55809 | 1 | 4 | Polybag |
02-55810 | 1 | 4 | Polybag |
A | B | C |
---|---|---|
1.18 | 1.29 | 0.39 |
A | B | C |
---|---|---|
1.51 | 1.63 | 0.44 |
A | B | C |
---|---|---|
1.65 | 1.89 | 0.43 |
A | B | C |
---|---|---|
2.13 | 2.3 | 0.53 |
A | B | C |
---|---|---|
3.01 | 2.7 | 0.59 |
A | B | C |
---|---|---|
4.8 | 3.59 | 0.71 |
A | B | C |
---|---|---|
4.8 | 3.59 | 0.71 |
WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov.
Anti-short bushings are inserted into the end of AC or FMC in order to protect the conductors from the sharp edges of the raceway where cut.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
02-55035 | 35 | 20 | Polybag |
02-55036 | 35 | 20 | Polybag |
02-55037 | 35 | 20 | Polybag |
02-55038 | 20 | 10 | Polybag |
02-55039 | 16 | 10 | Polybag |
A | B |
---|---|
0.39 | 0.35 |
A | B |
---|---|
0.45 | 0.41 |
A | B |
---|---|
0.59 | 0.54 |
A | B |
---|---|
0.78 | 0.73 |
A | B |
---|---|
0.99 | 0.94 |
WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov.
Snap-in connectors are used to terminate AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
44440 | 3 | 10 | Polybag |
AMC-50 | 50 | 2 | Contractor Pack |
44441 | 2 | 10 | Polybag |
AMC-75 | 25 | 2 | Contractor Pack |
A | B | C |
---|---|---|
1.33 | 0.98 | 1.72 |
A | B | C |
---|---|---|
1.65 | 1.34 | 2.02 |
Duplex snap-in connectors are used to terminate two runs of AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure.
Model Number | Retail Pack | Master Pack | Package Type |
---|---|---|---|
44450 | 2 | 12 | Polybag |
A | B | C |
---|---|---|
1.66 | 1.76 | 0.89 |