Electrical
Electrical

An extensive range of robust fittings and weatherproof products.

Automotive
Automotive

Connectivity solutions such as high brackets, busbars, and connector pins.

Power Transmission & Distribution
Power Transmission & Distribution

Connectors & structural components for cutouts, transformers, & substations.

Aerospace
Aerospace

Complex sensor housings & fracture-critical products.

Appliances
Appliances

Robust castings and assemblies for everyday appliances.

Commercial Hardware
Commercial Hardware

Finished components for commercial & residential hardware applications.

Electronics & Telecom
Electronics & Telecom

Precision metal stamped sensors, connectors and cast housings & covers.

Fluid Power
Fluid Power

Durable, precision products for high-pressure applications.

Food & Beverage
Food & Beverage

Handles, leveling pins, flow valves & button housings.

Lighting
Lighting

Custom housings to fully assembled commercial & industrial light fixtures.

Marine
Marine

Durable corrosion-resistant engineered castings and subassemblies.

Medical & Dental
Medical & Dental

Medical-grade parts for implants, housings, manifolds, and pumps.

Oil & Gas
Oil & Gas

Custom housings and covers for flow control, pressure valves & meters.

Power Tools
Power Tools

Durable yet lightweight custom metal housings.

Energy
Energy

Innovative precision metal stamped parts.

High Pressure Die Casting

High-pressure liquid metal is pressed into a precision metal mold cavity, and then cooled & solidified under pressure.

Ideal for a wide range of applications, including automotive, agricultural, electronics, and medical.

Sand Casting

Castings with complex shapes & inner cavities that are produced in a sand mold

Ideal for parts with complex shapes and inner cavities

Gravity Die Casting

A mold is filled with liquid metal using gravity and cooled and solidified in the mold to obtain a casting

Ideal for parts with complex shapes made with steel, aluminum or magnesium alloys

Investment Casting

A process used to obtain a mold without a parting surface; creates parts with high dimensional & geometric accuracy

Ideal for near-net shaped parts with complex shapes and high precision requirements

Partner Services

Custom Tooling, Machining, Surface Finishing, Special Purpose Machine Design & Development

Precision Metal Stamping

More than 80 presses convert metal sheets into custom parts

Ideal for parts for electronic connectors and microprocessor chips

Swiss Screw Machining

A specialized CNC machine capable of producing extremely small, precise parts

Ideal for complex miniature screws, contact pins & micro-fasteners

Partner Services

Rapid Prototypes, Heat Treating, Automated Assembly

Company History
Company History

Learn more about our company milestones.

Plant Locations
Plant Locations

Learn more about our global manufacturing facilities.

Company News
Company News

See our company announcements and press releases.

Contact Us
Contact Us

Let us know how we can help create a solution for you

Resources
Resources

Download catalogs and key product guides.

Global Code of Conduct
Global Code of Conduct

Download our Code of Conduct and report violations.

Innovation at Sigma

Purposeful innovation – the continual improvement and innovation of custom-designed and precision-made products and solutions.

Engineered Solutions

Sigma offers solutions for complex product characteristics and technical requirements.

Global Supply Chain Management

U.S.-based supply chain management teams support our customers.

Partner Services

Sigma is a vertically integrated single-source solution provider.

Sustainability at Sigma

Our commitment to excellence drives us to build a better, more sustainable future in all aspects of our operations.

Safety at Sigma

Safety is more than just a priority at Sigma Engineered Solutions – it’s a core value.

< Products

Double Snap Lock® Squeeze Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): 90 DegreeSqueeze
Feature(s): Double Snap Lock®InsulatedSnap Lock®

Double Snap Lock® squeeze connectors are used to terminate AC, MC or FMC/RWFMC to a knockout in a metal box or enclosure. The patented Double Snap Lock® design provides a faster installation. For dry location applications.

  • No tools required
  • 90° C rated throat insulator
  • Patent-pending design
  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
SSQ037DSI
SSQ050DSI
SSQ075DSI
ABCVolume
1.371.730
ABCVolume
1.682.060
ABCVolume
cCSAus: 174008

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Ground Rod Clamp

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Clamp
Connection Type(s): Ground Rod

Used to connect bare copper wire to copper ground rod or rebar

  • Cast from high strength, highly conductive copper alloy
  • All listed models approved for Direct Burial
    in earth and concrete
  • With stainless steel hex bolt
Model Number
HDC34SSS
ABCVolume
cULus: E88878

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Combination Ground Clamps for Bare Wire

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Clamp
Connection Type(s): Bare WireLay-In-Lug

Used to connect bare copper wire to water pipe or rebar

  • Available with lay-in style lug for fast and easy installation of ground wires
  • Cast from high strength, highly conductive copper alloy
  • All models approved for Direct Burial in earth and concrete
  • Stainless steel hardware
  • Perpendicular lug style
Model Number
RBC3SS
ABCVolume
cULus: E88878

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Combination Ground Clamps for Bare Wire

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Clamp
Connection Type(s): Bare WireFeed-thru

Used to connect bare copper wire to water pipe or rebar

  • Available with feed-through style lug for fast and easy installation of ground wires
  • Cast from high strength, highly conductive copper alloy
  • All models approved for Direct Burial in earth and concrete
  • Features super-compact design ideal for rebar grids, pools and spas
  • Stainless steel hardware
  • In-line lug style
Model Number
RBC1SS
ABCVolume
cULus: E88878

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Copper Intersystem Bonding Bridge with Conduit Adaptor

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Intersystem Bonding Bridge

IBBs are used in residential and commercial applications to ground up to 4 systems to a single location.

  • Meets NEC 2011 article 250.94
  • Lay-in lug style
  • Connection for up to 4 auxiliary
    ground wires (1 more than NEC requirement)
  • Approved for solid or stranded copper conductors
  • Supplied with PVC adaptor for 1/2″ pipe
  • Stainless steel screws
Model Number
IBBCUIN03
ABCVolume
4.331.581.39
cULus: E88878

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250.94
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

One-Gang While-In-Use Receptacle Cover – 3-1/8″ Deep

Material: Metal Die-Cast
Category: Weatherproof
Sub Category: Cover
Type(s): 1-Gang
Connection Type(s): While-In-Use
Feature(s): Extra Duty RatedHorizontalVertical

One-gang in-use receptacle covers allow an outlet to be utilized while the cover is closed in wet, damp or dry locations.

  • 16 configurations
  • Adaptable for GFCI, duplex, round and switch devices
  • 3-1/8″ deep
  • For vertical or horizontal installation
  • Lockable
  • Meets NEMA 3R and NEC’s “Extra Duty” Requirement
  • Includes adaptor plates, pre-installed gasket and hardware
Color Model Number
Gray WM10MDG1
White WM10MDW1
Bronze WM10MDA
ABC
5.984.023.12
cULus: E121488
cCSAus: 174008

Standards: UL 514D, CSA C22.2 No. 42.1-13
NEMA: NEMA 3R
Other: NEC 2020 Extra Duty
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

One-Gang While-In-Use Receptacle Cover – 2-1/4″ Deep

Material: Metal Die-Cast
Category: Weatherproof
Sub Category: Cover
Type(s): 1-Gang
Connection Type(s): While-In-Use
Feature(s): Extra Duty RatedHorizontalVertical

One-gang in-use receptacle covers allow an outlet to be utilized while the cover is closed in wet, damp or dry locations.

  • 16 configurations
  • Adaptable for GFCI, duplex, round and switch devices
  • 2-1/4″ deep
  • For vertical or horizontal installation
  • Lockable
  • Meets NEMA 3R and NEC’s “Extra Duty” Requirement
  • Includes adaptor plates, pre-installed gasket and hardware
Color Model Number
Gray WM10MSG1
White WM10MSW1
Bronze WM10MSA
ABC
5.984.022.64
cULus: E121488
cCSAus: 174008

Standards: UL 514D, CSA C22.2 No. 42.1-13
NEMA: NEMA 3R
Other: NEC 2020 Extra Duty
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Two-Gang While-In-Use Receptacle Cover

Material: Non-Metallic
Category: Weatherproof
Sub Category: Cover
Type(s): 2-Gang
Connection Type(s): While-In-Use
Feature(s): Extra Duty Rated

Two-gang in-use receptacle covers allow two receptacles to be utilized while the cover is closed in wet, damp or dry locations.

  • 55 configurations
  • Each side is adaptable for GFCI, duplex, round and switch devices
  • 3-1/8″ deep
  • Lockable
  • Meets NEMA 3R and NEC’s “Extra Duty” Requirement
  • Includes adaptor plates, pre-installed gasket and hardware
Color Model Number
Clear WL21MMDTG1
Bronze WL21MMDA1
Gray WL21MMDG1
White WL21MMDW1
ABC
6.025.633.5
cULus: E332841
cCSAus: 174008

Standards: UL 514D, CSA C22.2 No. 42.1-13
NEMA: NEMA 3R
Other: NEC 2020 Extra Duty
65!
WARNING:
Risk of reproductive harm from exposure to Bisphenol A (BPA).
See www.P65Warnings.ca.gov
< Products

One-Gang While-In-Use Receptacle Cover – 3-1/8″ Deep

Material: Non-Metallic
Category: Weatherproof
Sub Category: Cover
Type(s): 1-Gang
Connection Type(s): While-In-Use
Feature(s): Extra Duty RatedHorizontalVertical

One-gang in-use receptacle covers allow an outlet to be utilized while the cover is closed in wet, damp or dry locations.

  • 16 configurations
  • Adaptable for GFCI, duplex, round and switch devices
  • 3-1/8″ deep
  • For vertical or horizontal installation
  • Lockable
  • Meets NEMA 3R and NEC’s “Extra Duty” Requirement
  • Includes adaptor plates, pre-installed gasket and hardware
Color Model Number
Clear WL10MDTG1
Bronze WL10MDA1
Gray WL10MDG1
White WL10MDW1
cULus: E332841
cCSAus: 174008

Standards: UL 514D, CSA C22.2 No. 42.1-13
NEMA: NEMA 3R
Other: NEC 2020 Extra Duty
65!
WARNING:
Risk of reproductive harm from exposure to Bisphenol A (BPA).
See www.P65Warnings.ca.gov
< Products

One-Gang While-In-Use Receptacle Cover – 2-1/4″ Deep

Material: Non-Metallic
Category: Weatherproof
Sub Category: Cover
Type(s): 1-Gang
Connection Type(s): While-In-Use
Feature(s): Extra Duty RatedHorizontalVertical

One-gang in-use receptacle covers allow an outlet to be utilized while the cover is closed in wet, damp or dry locations.

  • 16 configurations
  • Adaptable for GFCI, duplex, round and switch devices
  • 2-1/4″ deep
  • For vertical or horizontal installation
  • Lockable
  • Meets NEMA 3R and NEC’s “Extra Duty” Requirement
  • Includes adaptor plates, pre-installed gasket and hardware
Color Model Number
Clear WL10MSTG1
Bronze WL10MSA1
Gray WL10MSG1
White WL10MSW1
cULus: E332841
cCSAus: 174008

Standards: UL 514D, CSA C22.2 No. 42.1-13
NEMA: NEMA 3R
Other: NEC 2020 Extra Duty
65!
WARNING:
Risk of reproductive harm from exposure to Bisphenol A (BPA).
See www.P65Warnings.ca.gov
< Products

Conduit-to-Box Combination Pull Elbow

Material: Zinc Die-Cast
Category: Fittings
Sub Category: EMTRigid
Type(s): ConnectorPull Elbow
Connection Type(s): 90 DegreeCombinationSet ScrewThreaded

Combination to box pull elbows are used to facilitate pulling conductors through a 90° bend in a run of IMC, Rigid or steel EMT conduit that terminates at a knockout in a metal box or enclosure. The removable cover gives ample access so that wire pulling can be achieved without any obstruction. For dry location applications.

  • Set screw for EMT and threaded for Rigid conduit or IMC
  • Removable aluminum cover and rubber gasket
Model Number
PE050CBG
PE075CBG
PE100CBG
PE125CBG
ABCVolume
1.3110.92
ABCVolume
1.371.271.17
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Water Tight Hub

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Water Tight Hub
Feature(s): Insulated

Water tight hubs are used to terminate rigid threaded conduit or IMC to enclosure.

  • Assembled with 90°C rated insulator and rubber sealing ring
  • UL listed and CSA certified for wet locations
  • Meets NEMA sealing requirements for Type 2, 3R, 4, 4X, 5 and 12 rated enclosures
  • Die-cast from high strength zinc alloy
Model Number
WTH050I
WTH075I
WTH100I
WTH125I
WTH150I
WTH200I
WTH250I
WTH300I
WTH350I
WTH400I
ABCVolume
1.431.50.55
ABCVolume
1.681.50.74
ABCVolume
21.810.94
ABCVolume
2.371.911.29
ABCVolume
2.751.881.51
ABCVolume
3.251.891.98
ABCVolume
3.782.62.41
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Water Tight Ground Nut

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Water Tight Nut

Used for securing water tight hubs

  • Available with bonding screw for grounding
  • Die-cast from high strength zinc alloy
Model Number
WTGN050
WTGN075
WTGN100
WTGN125
WTGN150
WTGN200
WTGN250
WTGN300
WTGN350
WTGN400
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Water Tight Hub

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Water Tight Hub

Used to terminate rigid threaded conduit or IMC to enclosure

  • UL listed and CSA certified for wet locations
  • Meets NEMA sealing requirements for Type 2, 3R, 4, 4X, 5 and 12 rated enclosures
Model Number
WTH050
WTH075
WTH100
WTH125
WTH150
WTH200
WTH250
WTH300
WTH350
WTH400
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Water Tight Hub with Grounding Screw

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Water Tight Hub
Feature(s): Insulated

Used to terminate rigid threaded conduit or IMC to enclosure

  • UL listed and CSA certified for wet locations
  • Meets NEMA sealing requirements for Type 2, 3R, 4, 4X, 5 and 12 rated enclosures
  • Assembled with 90°C rated insulator and rubber sealing ring
  • With bonding screw for grounding
Model Number
WTHG050I
WTHG075I
WTHG100I
WTHG125I
WTHG150I
WTHG200I
WTHG250I
WTHG300I
WTHG350I
WTHG400I
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Water Tight Connector

Material: Non-Metallic
Category: FittingsStrain Relief
Sub Category: Strain Relief
Type(s): Connector
Connection Type(s): Water Tight
Feature(s): with Mesh

Used to seal, provide strain relief and terminate portable or flexible cords to metal enclosure or box

  • Suitable for use with S, SO, ST, STO, SJ, SJT, SJTO, SJOOW, SOOW, STOOW, SJTOOW and SVO cords
  • Yellow Plastic fittings with stainless steel single/double weave mesh
  • Rubber grommet provides water-tight seal
Model Number
W5011M
W5012M
W5013M
W5015M
W5017M
W7512M
W7514M
W7516M
W7518M
W7519M
W7520M
W10018M
W10019M
W10021M
W10022M
W10023M
ABCVolume
ABCVolume
ABCVolume
cCSAus: 174008

Standards: UL 514B, CSA C22.2 No. 18.3-12
< Products

Water Tight Connector

Material: Non-Metallic
Category: FittingsStrain Relief
Sub Category: Strain Relief
Type(s): Connector
Connection Type(s): Water Tight
Feature(s): with Mesh

Used to seal, provide strain relief and terminate portable or flexible cords to metal enclosure or box

  • Suitable for use with S, SO, ST, STO, SJ, SJT, SJTO, SJOOW, SOOW, STOOW, SJTOOW and SVO cords
  • Yellow Plastic fittings with plastic single/double weave mesh
  • Rubber grommet provides water-tight seal
Model Number
W7514N
W7516N
W10019N
W10021N
W10023N
ABCVolume
ABCVolume
cCSAus: 174008

Standards: UL 514B, CSA C22.2 No. 18.3-12
< Products

Mounting Lugs

Material: Steel
Category: Weatherproof
Sub Category: Accessories
Type(s): Mounting Lugs

Mounting Lugs

  • Steel
Model Number
WPMH1
ABCVolume
< Products

Vaportight Guard

Material: Zinc Die-Cast
Category: Weatherproof
Sub Category: Lighting
Type(s): Vaportight Components
Connection Type(s): Guard
Feature(s): 100 WattWire Guard

Vaportight Guard

  • Wire Guard
  • For 100 Watt
Model Number
VGW1
ABCVolume
< Products

Vaportight Guard

Material: Zinc Die-Cast
Category: Weatherproof
Sub Category: Lighting
Type(s): Vaportight Components
Connection Type(s): Guard
Feature(s): 200 WattWire Guard

Vaportight Guard

  • Wire Guard
  • For 200 Watt
Model Number
VGW2
ABCVolume
< Products

Service Entrance Cable Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: NMSE
Type(s): Connector
Connection Type(s): Service Entrance Cable

Service entrance cable connectors are used for sealing and terminating Oval SE cable to a threaded entry of a watertight box or enclosure.

  • Wet location approved when used with a sealing locknut (not included)
  • Rubber grommet provides water-tight seal around cable
Model Number
WC1004
WC1006
WC1008
WC1251
WC1252
WC1253
WC15010
WC15020
WC20010
WC20020
WC20030
WC20040
WC20040L
ABCVolume
1.440.50.8
ABCVolume
1.440.440.7
ABCVolume
ABCVolume
ABCVolume
1.990.570.94
ABCVolume
ABCVolume
2.180.741.24
ABCVolume
ABCVolume
2.410.891.54
ABCVolume
2.4111.58
UL: E155410
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Underground Feeder (UF) Cable Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: NMSE
Type(s): Connector
Connection Type(s): Underground Feeder Cable

UF connectors are used to secure Underground Feeder cable to a metal enclosure or waterproof box with a threaded hub.

  • Wet location approved when used with a sealing locknut (not included)
Model Number
UFC050
UFC075
ABCVolume
1.260.220.44
ABCVolume
1.30.220.66
UL: E213494
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Vapor Plate with Gasket

Material: Plated
Category: Weatherproof
Sub Category: Lighting
Type(s): Vaportight Components
Connection Type(s): Plate

Vapor Plate with Gasket

  • Plated
Model Number
VAP1
ABCVolume
< Products

Vaportight Guard

Material: Zinc Die-Cast
Category: Weatherproof
Sub Category: Lighting
Type(s): Vaportight Components
Connection Type(s): Guard
Feature(s): 100 WattCast Guard

Vaportight Guard

  • Cast Guard
  • For 100 Watt
Model Number
VGC1
ABCVolume
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Two Way Tank Ground Connectors

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Connector
Connection Type(s): Tank Ground

Used for grounding connections on distribution transformer tanks

  • Cast from high strength, highly conductive copper alloy
  • Two way models accommodate cable in horizontal or vertical orientations
  • With tin plating
Model Number
TGT21ATP
ABCVolume
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Service Entrance Heads – Threaded Type

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: NMSE
Type(s): Service Entrance Head
Connection Type(s): Threaded

Threaded type head used with rigid conduit and IMC for pulling service drop conductors

  • Assembled with electrical grade insulator with multiple holes
  • UL listed and CSA certified for wet location use
  • Die-cast from high strength, corrosion and weather resistant aluminum alloy
Model Number
TH050
TH075
TH100
TH125
TH150
TH200
TH250
TH300
TH300L
TH350
TH400
TH500
TH600
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL,: E121487,
CSA,: LR57925,

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Three Piece Coupling

Material: Aluminum
Category: Fittings
Sub Category: Rigid
Type(s): Coupling
Connection Type(s): Three Piece

Used to connect two lengths of rigid threaded conduit or IMC, when neither conduit can be turned

Model Number
TPC050
TPC075
TPC100
TPC125
TPC150
TPC200
TPC250
TPC300
TPC350
TPC400
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E155411

Standards: UL 514B, CSA C22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Two Way Tank Ground Connectors

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Connector
Connection Type(s): Tank Ground

Used for grounding connections on distribution transformer tanks

  • Cast from high strength, highly conductive copper alloy
  • Two way models accommodate cable in horizontal or vertical orientations
Model Number
TGT12A
ABCVolume
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Two Way Tank Ground Connectors

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Connector
Connection Type(s): Tank Ground

Used for grounding connections on distribution transformer tanks

  • Cast from high strength, highly conductive copper alloy
  • Two way models accommodate cable in horizontal or vertical orientations
  • With tin plating
Model Number
TGT12ATP
ABCVolume
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Two Way Tank Ground Connectors

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Connector
Connection Type(s): Tank Ground

Used for grounding connections on distribution transformer tanks

  • Cast from high strength, highly conductive copper alloy
  • Two way models accommodate cable in horizontal or vertical orientations
Model Number
TGT21A
ABCVolume
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Tank Ground Connectors

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Connector
Connection Type(s): Tank Ground

Used for grounding connections on distribution transformer tanks

  • Cast from high strength, highly conductive copper alloy
  • With tin plating
Model Number
TGO11ATP
ABCVolume
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Tank Ground Connectors

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Connector
Connection Type(s): Tank Ground

Used for grounding connections on distribution transformer tanks

  • Cast from high strength, highly conductive copper alloy
Model Number
TGO20A
ABCVolume
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Tank Ground Connectors

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Connector
Connection Type(s): Tank Ground

Used for grounding connections on distribution transformer tanks

  • Cast from high strength, highly conductive copper alloy
  • With tin plating
Model Number
TGO20ATP
ABCVolume
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Squeeze Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): Squeeze

Squeeze connectors are used to terminate AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure.

  • Assembled with die cast locknut and zinc plated steel screws
  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
SSQ037
SSQ050
SSQ075
SSQ100
SSQ125
SSQ150
SSQ150U
SSQ200
SSQ200U
SSQ250
SSQ300
SSQ350
SSQ350U
SSQ400
ABCVolume
10.410.62
ABCVolume
1.50.50.99
ABCVolume
1.590.51.18
ABCVolume
1.750.551.44
ABCVolume
1.90.611.76
ABCVolume
2.030.612.06
ABCVolume
ABCVolume
2.10.612.55
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Squeeze Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): Squeeze
Feature(s): Insulated

Squeeze connectors are used to terminate AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure.

  • 90° C rated throat insulator
  • Assembled with die cast locknut and zinc plated steel screws
  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
SSQ037I
SSQ050I
SSQ075I
SSQ100I
SSQ125I
SSQ150I
SSQ200I
SSQ250I
SSQ300I
SSQ350I
SSQ400I
ABCVolume
1.080.490.62
ABCVolume
1.580.580.99
ABCVolume
1.680.581.18
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Tank Ground Connectors

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Connector
Connection Type(s): Tank Ground

Used for grounding connections on distribution transformer tanks

  • Cast from high strength, highly conductive copper alloy
Model Number
TGO11A
ABCVolume
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

90° Short Radius Elbow

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Elbow
Connection Type(s): 90 DegreeShort Radius

Used to connect threaded rigid conduit or IMC to a steel box or other enclosure where a close radius is desired

Model Number
SRE050
SRE075
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Service Entrance Heads – Set Screw Type

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: NMSE
Type(s): Service Entrance Head
Connection Type(s): Set Screw

Set screw type head used with rigid and IMC for pulling service drop conductors

  • Assembled with electrical grade insulator with multiple holes
  • UL listed and CSA certified for wet location use
  • Die-cast from high strength, corrosion and weather resistant aluminum alloy
Model Number
SS050
SS075
SS100
SS125
SS150
SS200
SS250
SS300
SS300L
SS350
SS400
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E121487
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body Cover

Material: Stamped Steel
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): Cover

Used in conjunction with gaskets when assembling conduit bodies to cover openings

  • Stamped steel covers used with malleable iron conduit bodies
  • Includes captive zinc plated, steel mounting screws
Model Number
SSC050
SSC075
SSC100
SSC150
SSC200
SSC300
SSC400
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E121488
CSA: LR57925

Standards: UL 514A & 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Service Entrance Elbow Conduit Body – Type LB

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): Type LB

Used with threaded rigid conduit or IMC for providing access to the interior of a conduit system for pulling, splicing, inspection and maintenance

  • Assembled with fiber gasket and aluminum die cast cover
  • UL listed for wet location use
  • Die cast from high strength, corrosion and weather resistant aluminum alloy
  • Extra long design
Model Number
SLBXL125
SLBXL200
ABCVolume
24.3
ABCVolume
63
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Locknut

Material: Steel
Category: Fittings
Sub Category: Rigid
Type(s): Locknut

Conduit locknuts are used for securing Rigid conduit, IMC and other threaded connectors to a steel outlet box or metal enclosure.

Model Number
SLN037
SLN050
SLN075
SLN100
SLN125
SLN150
SLN200
SLN250
SLN300
SLN400
ABCVolume
ABCVolume
1.120.091
ABCVolume
1.390.11.25
ABCVolume
1.70.131.56
ABCVolume
2.040.131.91
ABCVolume
2.360.132.16
ABCVolume
2.870.132.68
ABCVolume
3.520.163.25
ABCVolume
4.130.163.95
ABCVolume
< Products

Conduit Sill Plate

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: NMSE
Type(s): Sill Plate

Sill plates are used in conjunction with sealing compound to protect service entrance cable and to cover the hole where it enters the dwelling.

  • Supplied with mounting screws
  • For use with EMT conduit
Model Number
SPC050/075
SPC100
SPC125
SPC150
SPC200
ABCVolume
ABCVolume
3.012.531.26
ABCVolume
3.782.611.57
ABCVolume
ABCVolume
4.134.132.36
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Screw-In Coupling

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Flex
Type(s): Coupling
Connection Type(s): Screw-In

Screw-in type couplings are used to join two lengths of FMC where minimum spacing between conduit is desired. For dry location applications.

  • Screws into conduit
Model Number
SICP050
SICP075
SICP100
SICP125
SICP150
SICP200
ABCVolume
1.790.920.2
ABCVolume
2.111.130.22
ABCVolume
2.421.360.31
ABCVolume
2.761.750.31
ABCVolume
3.072.110.31
ABCVolume
3.282.670.31
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Service Entrance Elbow Conduit Body – Type LB

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): Type LB

Service entrance ells are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance.

  • Mounts flush against structures
  • Listed for use in wet locations
  • Assembled with removable cover and fiber gasket
Model Number
SLB050
SLB075
SLB100
SLB125
SLB150
SLB200
ABCVolume
3.151.191.451.8
ABCVolume
3.571.521.773.8
ABCVolume
4.181.751.975.7
ABCVolume
5.392.192.4413.5
ABCVolume
6.12.362.4417
ABCVolume
6.612.872.9329.3
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Service Entrance Elbow Conduit Body – Type LB

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): Type LB

Used with threaded rigid conduit or IMC for providing access to the interior of a conduit system for pulling, splicing, inspection and maintenance

  • Assembled with fiber gasket and aluminum die cast cover
  • UL listed for wet location use
  • Die cast from high strength, corrosion and weather resistant aluminum alloy
Model Number
SLB050CN
SLB075CN
SLB100CN
ABCVolume
1.8
ABCVolume
3.8
ABCVolume
5.7
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Screw-In Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): Screw-In

Screw-in type connectors are used to terminate FMC to a knockout in a dry location box or enclosure.

  • Screws into conduit
Model Number
SICN037
SICN050
SICN075
SICN100
SICN125
SICN150
SICN200
ABCVolume
1.280.920.46
ABCVolume
1.350.920.41
ABCVolume
1.611.130.39
ABCVolume
1.931.360.54
ABCVolume
2.131.750.61
ABCVolume
2.322.110.63
ABCVolume
2.562.670.76
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Screw-In Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): Screw-In
Feature(s): Insulated

Screw-in type connectors are used to terminate FMC to a knockout in a dry location box or enclosure.

  • Screws into conduit
  • 90° C rated throat insulator
Model Number
SICN037I
SICN050I
SICN075I
SICN100I
SICN125I
SICN150I
SICN200I
ABCVolume
1.360.920.46
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Snap Lock® Screw-In Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): Screw-In
Feature(s): Snap Lock®

Snap Lock® screw-in type connectors are used to terminate FMC/RWFMC to a knockout in a dry location box or enclosure.

  • Faster installation with no locknut required
  • Screws into conduit
Model Number
SICN037S
SICN050S
ABCVolume
1.190.830.4
ABCVolume
1.270.830.4
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Set Screw Connector

Material: Zinc-Plated Steel
Category: Fittings
Sub Category: EMT
Type(s): Connector
Connection Type(s): Set Screw

Set screw type connectors are used to secure and terminate EMT conduit to a knockout in a metal box or enclosure. For dry location applications.

  • Concrete-tight when taped
  • 1-1/4″ to 3″ double set screw
Model Number
SESN050
SESN075
SESN100
SESN125
SESN150
SESN200
ABCVolume
1.220.410.65
ABCVolume
1.30.410.86
ABCVolume
1.610.431.11
ABCVolume
2.30.651.41
ABCVolume
2.40.691.65
ABCVolume
2.440.712.13
cULus: E210498

Standards: UL 514B, CSA C22.2 No. 18.3-12
< Products

Insulated Set Screw Connector

Material: Zinc-Plated Steel
Category: Fittings
Sub Category: EMT
Type(s): Connector
Connection Type(s): Set Screw
Feature(s): Insulated

Set screw type connectors are used to secure and terminate EMT conduit to a knockout in a metal box or enclosure. For dry location applications.

  • With 90°C rated insulator
  • Concrete-tight when taped
  • 1-1/4″ to 2″ double set screw
Model Number
SESN050I
SESN075I
SESN100I
SESN125I
SESN150I
SESN200I
ABCVolume
1.220.410.65
ABCVolume
1.30.410.86
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E210498

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of reproductive harm from exposure to Bisphenol A (BPA).
See www.P65Warnings.ca.gov
< Products

Set Screw Coupling

Material: Zinc-Plated Steel
Category: Fittings
Sub Category: EMT
Type(s): Coupling
Connection Type(s): Set Screw

Set screw type couplings are used to join lengths of steel EMT conduit. For dry location applications.

  • Concrete-tight when taped
  • 1-1/4″ to 3″ double set screw
Model Number
SESP050
SESP075
SESP100
SESP125
SESP150
SESP200
ABCVolume
1.570.840.73
ABCVolume
1.571.060.94
ABCVolume
1.861.311.19
ABCVolume
2.951.711.53
ABCVolume
2.951.941.76
ABCVolume
3.232.392.22
cULus: E210498

Standards: UL 514B, CSA C22.2 No. 18.3-12
< Products

Compression Connector

Material: Zinc-Plated Steel
Category: Fittings
Sub Category: EMT
Type(s): Connector
Connection Type(s): Compression

Compression type connectors are used to secure and terminate steel EMT conduit to a knockout in a metal box or enclosure. For dry location applications.

  • Concrete-tight
  • 2-1/2” and 3” also listed for Rigid conduit or IMC
Model Number
SECN050
SECN075
SECN100
SECN125
SECN150
SECN200
ABCVolume
1.311.050.5
ABCVolume
1.481.280.52
ABCVolume
1.531.560.64
ABCVolume
1.71.940.68
ABCVolume
1.962.170.72
ABCVolume
2.072.680.72
cULus: E210498

Standards: UL 514B, CSA C22.2 No. 18.3-12
< Products

Insulated Compression Connector

Material: Zinc-Plated Steel
Category: Fittings
Sub Category: EMT
Type(s): Connector
Connection Type(s): Compression
Feature(s): Insulated

Compression type connectors are used to secure and terminate steel EMT conduit to a knockout in a metal box or enclosure. For dry location applications.

  • With 90° C rated insulator
  • Concrete-tight
Model Number
SECN050I
SECN075I
SECN100I
SECN125I
SECN150I
SECN200I
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E210498

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of reproductive harm from exposure to Bisphenol A (BPA).
See www.P65Warnings.ca.gov
< Products

Compression Coupling

Material: Zinc-Plated Steel
Category: Fittings
Sub Category: EMT
Type(s): Coupling
Connection Type(s): Compression

Compression type couplings are used to join lengths of steel EMT conduit. For dry location applications.

  • Concrete-tight
Model Number
SECP050
SECP075
SECP100
SECP125
SECP150
SECP200
ABCVolume
1.640.721.05
ABCVolume
1.80.941.28
ABCVolume
1.881.181.56
ABCVolume
2.091.541.94
ABCVolume
2.41.752.17
ABCVolume
2.332.222.68
cULus: E210498

Standards: UL 514B, CSA C22.2 No. 18.3-12
< Products

Insulated Set Screw Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: EMTRigid
Type(s): Connector
Connection Type(s): Set Screw
Feature(s): Insulated

Set screw type connectors are used to secure and terminate EMT conduit to a knockout in a metal box or enclosure. For dry location applications.

  • With 90° C rated insulator
  • Concrete-tight when taped
  • 1-1/4″ to 4″ double set screw
Model Number
SCON050I
SCON075I
SCON100I
SCON125I
SCON150I
SCON200I
SCON250I
SCON300I
SCON350I
SCON400I
ABCVolume
1.140.390.72
ABCVolume
1.410.460.93
ABCVolume
1.530.531.17
ABCVolume
2.020.631.52
ABCVolume
2.250.711.75
ABCVolume
2.550.752.2
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E210498
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Set Screw Coupling

Material: Zinc Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): Coupling
Connection Type(s): Set Screw

Set screw type couplings are used to join lengths of steel EMT conduit. For dry location applications.

  • Concrete-tight when taped
  • Double set screw
  • 2-1/2” to 4” approved for Rigid
Model Number
SCOP050
SCOP075
SCOP100
SCOP125
SCOP150
SCOP200
SCOP250
SCOP300
SCOP350
SCOP400
ABCVolume
1.340.930.72
ABCVolume
1.711.140.93
ABCVolume
1.851.421.17
ABCVolume
2.51.821.52
ABCVolume
2.872.071.75
ABCVolume
3.442.542.21
ABCVolume
4.023.292.9
ABCVolume
4.493.923.53
ABCVolume
ABCVolume
UL: E210498
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

SE Clamp Type Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: NMSE
Type(s): Connector
Connection Type(s): Clamp Type

Clamp type connectors are used to terminate Oval SE cables to a knockout in a dry location box or enclosure.

Model Number
SEC125
SEC150
SEC200
ABCVolume
1.312.260.59
ABCVolume
1.332.850.62
ABCVolume
1.573.50.72
UL: E155410
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Strap Squeeze Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): Squeeze

Used to terminate flexible metal conduit, armored or metal clad cables to an enclosure or outlet box

  • Assembled with die-cast zinc locknut and zinc plated steel screw
  • Die-cast from high strength zinc alloy
  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
SC050
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Oval Service Entrance Head

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: NMSE
Type(s): Service Entrance Head
Connection Type(s): Oval Type

Die-cast oval service entrance caps are used as a connecting point in an overhead service entrance for Oval SE cable.

  • Removable cap
  • Two piece phenolic insulator
  • Listed for use in dry locations
Model Number
SCEH1
SCEH2
ABCVolume
2.922.453.22
ABCVolume
4.483.41.97
UL: E155410
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Set Screw Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): Connector
Connection Type(s): Set Screw

Set screw type connectors are used to secure and terminate EMT conduit to a knockout in a metal box or enclosure. For dry location applications.

  • Concrete-tight when taped
  • 1-1/4″ to 4″ double set screw
  • 2-1/2” to 4” approved for Rigid
Model Number
SCON050
SCON075
SCON100
SCON125
SCON150
SCON200
SCON250
SCON300
SCON350
SCON400
ABCVolume
1.070.390.72
ABCVolume
1.330.460.93
ABCVolume
1.460.531.17
ABCVolume
1.940.631.52
ABCVolume
2.180.711.75
ABCVolume
2.490.752.2
ABCVolume
3.091.042.91
ABCVolume
3.391.063.53
ABCVolume
ABCVolume
UL: E210498
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Saddle Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): Saddle

Saddle connectors are used to terminate NM, AC or MC to a knockout in a dry location box or enclosure.

  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
SAD037
ABCVolume
0.91.610.9
cULus: E155411

65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Saddle Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): Saddle

Used to terminate non-metallic, armored or metal clad cables to an enclosure or outlet box

  • Die-cast from high strength zinc alloy
  • Die-cast clamp
  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
SAD037DC
SAD050DC
SAD075DC
SAD100DC
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E155411

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Snap Lock® Saddle Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): Saddle
Feature(s): Snap Lock®

Snap Lock® saddle connectors are used to terminate NM, AC or MC to a knockout in a dry location box or enclosure.

  • Faster installation with no locknut required
  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
SAD037S
ABCVolume
1.651.040.93
cULus: E155411

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Reducing Washer

Material: Zinc-Plated Steel
Category: Fittings
Sub Category: Rigid
Type(s): Washer
Connection Type(s): Reducing

Reducing washers are used to reduce the size of a knockout in a steel outlet box or metal enclosure. Two reducing washers are required for each knockout.

  • Embossed for self-centering
Model Number
RW075/050
RW100/050
RW100/075
RW125/050
RW125/075
RW125/100
RW150/050
RW150/075
RW150/100
RW150/125
RW200/050
RW200/075
RW200/100
RW200/125
RW200/150
RW250/050
RW250/075
RW250/100
RW250/125
RW250/150
RW250/200
ABCVolume
0.871.440.04
ABCVolume
0.871.750.04
ABCVolume
1.111.750.04
ABCVolume
0.872.190.04
ABCVolume
1.112.190.04
ABCVolume
1.372.190.04
ABCVolume
0.872.440.04
ABCVolume
ABCVolume
1.372.440.04
ABCVolume
1.722.440.04
ABCVolume
ABCVolume
ABCVolume
ABCVolume
1.7230.04
ABCVolume
1.9830.04
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
2.463.50.04
cULus: E121487

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Clamp Type Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: NMSE
Type(s): Connector
Connection Type(s): Clamp Type

Clamp type connectors are used to terminate NM Sheathed cable, Flexible Cord, Oval or Round SE cables to a knockout in a dry location box or enclosure.

  • Male hub threads NPS
  • Assembled with die cast locknut and zinc plated screws
  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
RX037
RX037U
RX075
RX100
RX100U
RX125
RX150
RX200
ABCVolume
0.741.160.36
ABCVolume
ABCVolume
0.951.670.44
ABCVolume
1.11.940.52
ABCVolume
ABCVolume
1.252.180.63
ABCVolume
1.442.610.64
ABCVolume
1.572.950.81
UL: E213494,E155410
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Snap Lock® Clamp Type Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: NMSE
Type(s): Connector
Connection Type(s): Clamp Type
Feature(s): Snap Lock®

Snap Lock® clamp type connectors are used to terminate NM Sheathed, Flexible Cord, Oval or Round SE cables to a knockout in a dry location box or enclosure. The Snap Lock® design requires no tools when attaching to the box for faster installation.

  • Faster installation – no locknut assembly
  • Assembled with die cast locknut and zinc plated screws
  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
RX037S
RX075S
ABCVolume
0.861.170.39
ABCVolume
11.670.47
cULus: E213494

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Rigid Set Screw Connectors

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Connector
Connection Type(s): Set Screw

Used to connect threadless rigid conduit or IMC to a steel box or other enclosure

Model Number
RSCN050
RSCN075
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Ground Rod Clamp

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Clamp
Connection Type(s): Ground Rod

Ground rod clamps are used to connect bare copper conductors directly to a driven ground rod.,Used to connect bare copper wire to copper ground rod or rebar

  • Suitable for direct burial in ground and concrete
  • Stainless steel screw,All listed models approved for Direct Burial
    in earth and concrete
  • With stainless steel hex bolt
Model Number
R11SS
R22SS
R33SS
ABCVolume
0.830.641.2
ABCVolume
0.940.661.34
ABCVolume
cULus: E88878

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Threaded Coupling

Material: Galvanized Steel
Category: Fittings
Sub Category: Rigid
Type(s): Coupling
Connection Type(s): Threaded

Threaded couplings are used to join two lengths of threaded Rigid conduit or IMC.

Model Number
RTC050
RTC075
RTC100
RTC125
RTC150
RTC200
RTC250
ABCVolume
1.011.630
ABCVolume
1.251.640
ABCVolume
1.521.970
ABCVolume
1.872.030
ABCVolume
2.152.060
ABCVolume
2.652.130
ABCVolume
3.253.190
cULus: E468931

Standards: UL 6, CSA C22.2 No. 45.1-07
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Threaded Nipple

Material: Galvanized Steel
Category: Fittings
Sub Category: Rigid
Type(s): Nipple
Connection Type(s): Threaded

Threaded nipples are used to extend a length of threaded Rigid conduit or IMC. May also be used to connect two steel outlet boxes or metal enclosures together.

Model Number
RN050/150
RN050/200
RN050/300
RN050/400
RN050/500
RN050/600
RN050/CL
RN075/150
RN075/200
RN075/300
RN075/400
RN075/500
RN075/600
RN075/CL
RN100/200
RN100/300
RN100/600
RN100/CL
RN125/200
RN125/300
RN125/600
RN125/CL
RN150/600
RN150/CL
RN200/1000
RN200/300
RN200/400
RN200/500
RN200/600
RN200/800
RN200/CL
RN250/400
RN300/400
ABCVolume
0.51.5
ABCVolume
0.52
ABCVolume
0.53
ABCVolume
0.54
ABCVolume
0.55
ABCVolume
0.56
ABCVolume
0.51.12
ABCVolume
0.751.5
ABCVolume
0.752
ABCVolume
0.753
ABCVolume
0.754
ABCVolume
0.755
ABCVolume
0.756
ABCVolume
0.751.37
ABCVolume
12
ABCVolume
13
ABCVolume
16
ABCVolume
11.5
ABCVolume
1.252
ABCVolume
1.253
ABCVolume
1.256
ABCVolume
1.251.63
ABCVolume
1.56
ABCVolume
1.51.75
ABCVolume
21
ABCVolume
23
ABCVolume
24
ABCVolume
25
ABCVolume
26
ABCVolume
28
ABCVolume
22
ABCVolume
2.54
ABCVolume
34
cULus: E468931

Standards: UL 6, CSA C22.2 No. 45.1-07
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

One-Hole Strap

Material: Zinc-Plated Steel
Category: Fittings
Sub Category: Rigid
Type(s): Strap
Connection Type(s): One-Hole

One-hole straps are used for providing support for Rigid conduit or IMC as required by the National Electrical Code (NEC).

  • Snap-on type
Model Number
RS0501
RS0751
RS1001
RS1251
RS1501
RS2001
RS2501
RS3001
ABCVolume
1.850.630.91
ABCVolume
2.20.751.13
ABCVolume
2.60.881.33
ABCVolume
2.950.891.65
ABCVolume
3.621.021.91
ABCVolume
4.091.142.32
ABCVolume
51.252.75
ABCVolume
5.531.253.6
cULus: E229278

Standards: UL 2239, CSA C22.2 No. 18.4-15
< Products

Two-Hole Strap

Material: Zinc-Plated Steel
Category: Fittings
Sub Category: Rigid
Type(s): Strap
Connection Type(s): Two-Hole

Two-hole straps are used for providing support for Rigid conduit or IMC as required by the National Electrical Code (NEC) where higher load bearing supports are desired.

  • Snap-on type
  • ,Also listed for use with EMT and FMC
Model Number
RS0502
RS0752
RS1002
RS1252
RS1502
RS2002
RS2502
RS3002
RS3502
RS4002
ABCVolume
2.480.620.87
ABCVolume
2.910.690.98
ABCVolume
3.370.751.3
ABCVolume
4.090.891.61
ABCVolume
4.410.941.91
ABCVolume
5.1212.31
ABCVolume
6.061.12.96
ABCVolume
6.461.13.58
ABCVolume
ABCVolume
cULus: E229278

Standards: UL 2239, CSA C22.2 No. 18.4-15
< Products

Combination Ground Clamps for Bare Wire

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Clamp
Connection Type(s): Bare WireLay-In-Lug

Used to connect bare copper wire to water pipe or rebar

  • Available with lay-in style lug for fast and easy installation of ground wires
  • Cast from high strength, highly conductive copper alloy
  • All models approved for Direct Burial in earth and concrete
  • Bronze hardware
  • Perpendicular lug style
Model Number
RBC3D
ABCVolume
cULus: E88878

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Ground Clamp with Lay-In Lug

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Clamp
Connection Type(s): Bare WireLay-In-Lug

Ground clamps with lay-in lug are used to connect a ground wire in Rigid conduit or Rebar to copper or galvanized steel water pipe.

  • Suitable for direct burial in ground and concrete
Model Number
RBC4D
ABCVolume
2.281.50.95
cULus: E88878

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

90˚ Rigid Elbow

Material: Galvanized Steel
Category: Fittings
Sub Category: Rigid
Type(s): Elbow
Connection Type(s): 90 Degree

90° rigid elbows are used to connect Rigid conduit or IMC together to allow for 90° bends.

Model Number
REN050
REN075
REN100
REN125
REN150
REN200
ABCVolume
4.026.381.5
ABCVolume
4.497.441.5
ABCVolume
5.758.841.89
ABCVolume
7.2410.122.01
ABCVolume
8.2711.942.01
ABCVolume
9.4914.082.01
cULus: E468931

Standards: UL 6, CSA C22.2 No. 45.1-07
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Reducing Bushing

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): Reducing

Reducing bushings are used to reduce the entry size of threaded conduit to allow joining conduits of two different sizes.

Model Number
RB075/050
RB100/050
RB100/075
ABCVolume
0.630.820.16
ABCVolume
0.7110.14
ABCVolume
0.7110.14
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Combination Ground Clamps for Bare Wire

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Clamp
Connection Type(s): Bare WireFeed-thru

Used to connect bare copper wire to water pipe or rebar

  • Available with feed-through style lug for fast and easy installation of ground wires
  • Cast from high strength, highly conductive copper alloy
  • All models approved for Direct Burial in earth and concrete
  • Features super-compact design ideal for rebar grids, pools and spas
  • Bronze hardware
  • In-line lug style
Model Number
RBC1D
ABCVolume
cULus: E88878

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Combination Ground Clamps for Bare Wire

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Clamp
Connection Type(s): Bare WireLay-In-Lug

Used to connect bare copper wire to water pipe or rebar

  • Available with lay-in style lug for fast and easy installation of ground wires
  • Cast from high strength, highly conductive copper alloy
  • All models approved for Direct Burial in earth and concrete
  • Bronze hardware or Stainless steel hardware available
  • In-line lug style
Model Number
RBC2D
RBC2SS
ABCVolume
cULus: E88878

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

NM Cable Connector

Material: Non-Metallic
Category: Fittings
Sub Category: NMSE
Type(s): Connector
Connection Type(s): NM Cable

NM cable connectors are used to terminate NM Sheathed cable to a knockout in a dry location box or enclosure.

  • Easy snap-in construction
  • Wide variety of cable configurations
Model Number
PNMR037
PNMR075
ABCVolume
0.660.980
ABCVolume
1.290.580
cULus: E213494

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of reproductive harm from exposure to Bisphenol A (BPA).
See www.P65Warnings.ca.gov
< Products

Ground Rod Clamp

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Clamp
Connection Type(s): Ground Rod

Used to connect bare copper wire to copper ground rod or rebar,Ground rod clamps are used to connect bare copper conductors directly to a driven ground rod.

  • Cast from high strength, highly conductive copper alloy,Suitable for direct burial in ground and concrete
  • All listed models approved for Direct Burial
    in earth and concrete,
  • With bronze hex bolt
Model Number
R1
R10
R11
R2
R22
R3
R33
ABCVolume
ABCVolume
ABCVolume
0.830.641.2
ABCVolume
ABCVolume
0.940.661.34
ABCVolume
ABCVolume
cULus,: E88878,

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Universal Ground Rod Clamp

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Clamp
Connection Type(s): Ground Rod

Ground rod clamps are used to connect bare copper conductors directly to a driven ground rod.

  • For steel rebar trade sizes 4 to 5
  • Suitable for direct burial in ground and concrete
  • Stainless steel screw
Model Number
R11USS
ABCVolume
1.060.631.63
cULus: E88878

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

90° Liquid-Tight Connector

Material: Non-Metallic
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): 90 Degree

Used to terminate and seal liquid-tight flexible metal and non-metallic type B conduit to a box or enclosure at a 90° angle

  • Connectors can be used with tapered female entry or unthreaded knock out using the provided sealing washer and locknut
  • Made from high grade plastic
Model Number
PLTA050B
PLTA075B
PLTA100B
ABCVolume
ABCVolume
ABCVolume
cCSAus: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
< Products

Straight Liquid-Tight Connector

Material: Non-Metallic
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): Straight

Straight liquid-tight connectors are used to terminate and seal Liquid-Tight Flexible Metal and/or Non-Metallic Type B Conduits to an oil-tight, liquid-tight or rain-tight box or enclosure. Connectors can be used with tapered threaded female entry or unthreaded knockout using the provided sealing washer and locknut.

  • Furnished with sealing ring
  • For Non-Metallic Type B Conduit
Model Number
PLTS037
PLTS050
PLTS075
PLTS100
PLTS125
ABCVolume
ABCVolume
21.40.54
ABCVolume
2.171.680.68
ABCVolume
2.2420.69
ABCVolume
cCSAus: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
< Products

Straight Liquid-Tight Connector

Material: Non-Metallic
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): Straight

Used to terminate and seal liquid-tight flexible metal and non-metallic type B conduit to a box or enclosure

  • Connectors can be used with tapered female entry or unthreaded knock out using the provided sealing washer and locknut
  • Made from high grade plastic
Model Number
PLTS050B
PLTS075B
PLTS100B
PLTS125B
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cCSAus: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
< Products

Rigid-to-Rigid Pull Elbow

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): CouplingPull Elbow
Connection Type(s): 90 DegreeThreaded

Used to make a 90° connection with two runs of threaded rigid conduit or IMC

  • Removable aluminum cover permits access for wire pulling
  • Cast from high strength zinc alloy
Model Number
PE050RR
PE075RR
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Rigid-to-Rigid Pull Elbow

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): CouplingPull Elbow
Connection Type(s): 90 DegreeThreaded

Rigid-to-rigid pull elbows are used to facilitate pulling conductors through a 90° bend between two runs of threaded Rigid conduit or IMC. The removable cover gives ample access so that wire pulling can be achieved without any obstructions.

  • Assembled with removable cover and gasket
  • Stamped aluminum cover
  • Rubber gasket
Model Number
PE050RRG
PE075RRG
PE100RRG
PE125RRG
ABCVolume
1.3110.92
ABCVolume
1.371.271.17
ABCVolume
1.951.571.46
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

90° Liquid-Tight Connector

Material: Non-Metallic
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): 90 Degree

90° liquid-tight connectors are used to terminate and seal Liquid-Tight Flexible Metal and/or Non-Metallic Type B Conduits at 90° angles to an oil-tight, liquid-tight or rain-tight box or enclosure. Connectors can be used with tapered threaded female entry or unthreaded knockout using the provided sealing washer and locknut.

  • Furnished with sealing ring
  • For Non-Metallic Type B Conduit
Model Number
PLTA037
PLTA050
PLTA075
PLTA100
ABCVolume
ABCVolume
1.351.060.54
ABCVolume
1.631.320.63
ABCVolume
1.871.60.69
cCSAus: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
< Products

EMT-to-EMT Pull Elbow

Material: Zinc Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): CouplingPull Elbow
Connection Type(s): 90 DegreeSet Screw

Used to make a 90° connection of two runs of steel EMT conduit

  • Removable aluminum cover permits access for wire pulling
  • Cast from high strength zinc alloy
  • Furnished with rubber gasket
Model Number
PE050EEG
PE075EEG
PE100EEG
PE125EEG
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Rigid-to-Box Pull Elbow

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): ConnectorPull Elbow
Connection Type(s): 90 DegreeThreaded

Used to make a 90° connection of Threaded Rigid conduit or IMC to a metal box or enclosure

  • Removable aluminum cover permits access for wire pulling
  • Cast from high strength zinc alloy
Model Number
PE050RB
PE075RB
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Rigid-to-Box Pull Elbow

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): ConnectorPull Elbow
Connection Type(s): 90 DegreeThreaded

Rigid-to-box pull elbows are used to connect threaded Rigid conduit or IMC to a box where a 90° bend is required. They facilitate pulling conductors through the bend and the removable cover gives ample access so that wire pulling can be achieved without any obstructions.

  • Assembled with removable cover and gasket
  • Stamped aluminum cover
  • Rubber gasket
Model Number
PE050RBG
PE075RBG
PE100RBG
PE125RBG
ABCVolume
1.3110.92
ABCVolume
1.371.271.17
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

EMT-to-Box Pull Elbow

Material: Zinc Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): ConnectorPull Elbow
Connection Type(s): 90 DegreeSet Screw

EMT-to-box pull elbows are used to facilitate pulling conductors through a 90° bend in a run of steel EMT conduit that terminates at a knockout in a metal box or enclosure. The removable cover gives ample access so that wire pulling can be achieved without any obstruction. For dry location applications.

  • Set screw type
  • Removable aluminum cover
Model Number
PE050EB
PE075EB
PE100EB
PE125EB
ABCVolume
1.3110.92
ABCVolume
1.371.271.17
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

EMT-to-Box Pull Elbow

Material: Zinc Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): ConnectorPull Elbow
Connection Type(s): 90 DegreeSet Screw

Used to make a 90° connection of Steel EMT conduit to a metal box or enclosure

  • Removable aluminum cover permits access for wire pulling
  • Cast from high strength zinc alloy
  • Furnished with rubber gasket
Model Number
PE050EBG
PE075EBG
PE100EBG
PE125EBG
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

EMT-to-EMT Pull Elbow

Material: Zinc Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): CouplingPull Elbow
Connection Type(s): 90 DegreeSet Screw

EMT-to-EMT pull elbows are used to facilitate pulling conductors through a 90° bend in two runs of steel EMT conduit. The removable cover gives ample access so that wire pulling can be achieved without any obstruction. For dry location applications.

  • Set screw type
  • Removable aluminum cover
Model Number
PE050EE
PE075EE
PE100EE
PE125EE
ABCVolume
1.3110.92
ABCVolume
1.371.271.17
ABCVolume
1.951.571.46
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Offset Nipple

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Nipple
Connection Type(s): Offset

Offset nipples are used to provide an offset connection between two outlet boxes or metal enclosures.

  • 3/4″ axis
Model Number
ON050
ON075
ON100
ON125
ON150
ON200
ON250
ON300
ABCVolume
2.420.940.43
ABCVolume
2.41.180.43
ABCVolume
2.721.450.6
ABCVolume
2.811.810.59
ABCVolume
3.032.050.71
ABCVolume
3.152.570.77
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Plastic Insulating Bushing

Material: Non-Metallic
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): Insulating

Plastic insulating bushings are used on the end of Rigid conduit, IMC and other threaded connectors to provide a smooth, well-rounded bearing surface to protect wires or cables.

  • Rated 105°C
  • Flame retardant
Model Number
PB050
PB075
PB100
PB125
PB150
PB200
PB250
PB300
PB350
PB400
ABCVolume
1.050.360.6
ABCVolume
1.290.40.78
ABCVolume
1.630.491
ABCVolume
1.930.481.3
ABCVolume
2.180.481.52
ABCVolume
2.640.541.95
ABCVolume
3.250.632.33
ABCVolume
3.90.682.9
ABCVolume
ABCVolume
cULus: E121487

Standards: UL 514B, CSA C22.2 No. 18.3-12
< Products

Conduit-to-Conduit Combination Pull Elbow

Material: Zinc Die-Cast
Category: Fittings
Sub Category: EMTRigid
Type(s): CouplingPull Elbow
Connection Type(s): 90 DegreeCombinationSet ScrewThreaded

Combination pull elbows are used to facilitate pulling conductors through a 90° bend in two runs of IMC, Rigid or steel EMT conduit. The removable cover gives ample access so that wire pulling can be achieved without any obstruction. For dry location applications.

  • Set screw for EMT and threaded for Rigid conduit or IMC
  • Removable aluminum cover and rubber gasket
Model Number
PE050CCG
PE075CCG
PE100CCG
PE125CCG
ABCVolume
1.3110.92
ABCVolume
1.371.271.17
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Nail Plate

Material: Zinc-Plated Steel
Category: Fittings
Sub Category: Accessories
Type(s): Nail Plate

Safety nail plates are used to protect cable insulation from nail punctures in wooden structures.

Model Number
NP02
NP01
ABCVolume
51.50.06
ABCVolume
2.51.50.06
cCSAus: 174008

< Products

EMT-to-Box Offset Compression Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): Connector
Connection Type(s): CompressionOffset

Compression type offset connectors are used to make a slight adjustment in terminating the end of a run of steel EMT conduit to a metal box or enclosure. For dry location applications.

  • Concrete-tight
Model Number
OCC050
OCC075
OCC100
ABCVolume
2.050.980.47
ABCVolume
2.851.230.47
ABCVolume
UL: E210498
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

EMT-to-Box Offset Set Screw Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): Connector
Connection Type(s): OffsetSet Screw

Set screw type offset connectors are used to make a slight adjustment in terminating the end of a run of steel EMT conduit to a metal box or enclosure. For dry location applications.

  • Concrete-tight when taped
Model Number
OCS050
OCS075
OCS100
ABCVolume
2.090.930.41
ABCVolume
3.021.120.47
ABCVolume
3.151.420.55
UL: E210498
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body Gasket

Material: Rubber
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): Gasket

Used with aluminum conduit bodies to seal enclosure with covers

Model Number
NG050
NG075
NG100
NG150
NG200
NG300
NG400
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl)phthalate.
See www.P65Warnings.ca.gov
< Products

Conduit Body Gasket

Material: Rubber
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): Gasket

Used with Form 5 conduit bodies to seal enclosure with covers

  • Can be converted to open type gaskets by tearing out center section along scored line
Model Number
NGT050
NGT075
NGT100
NGT150
NGT200
NGT300
NGT400
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl)phthalate.
See www.P65Warnings.ca.gov
< Products

Nail Plate

Material: Zinc-Plated Steel
Category: Fittings
Sub Category: Accessories
Type(s): Nail Plate

Safety nail plates are used to protect cable insulation from nail punctures in wooden structures.

Model Number
NP01
NP02
ABCVolume
2.51.50.06
ABCVolume
51.50.06
cCSAus: 174008

< Products

Insulated Squeeze Connector

Material: Malleable Iron
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): Squeeze
Feature(s): Insulated

Used to terminate flexible metal conduit, armored or metal clad cables to an enclosure or outlet box

  • Assembled with steel locknut and zinc plated steel screws
  • 90° C rated throat insulator
  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
MSSQ037I
MSSQ050I
MSSQ075I
MSSQ100I
MSSQ125I
MSSQ150I
MSSQ200I
MSSQ250I
MSSQ300I
MSSQ350I
MSSQ400I
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Service Entrance Heads – Mast Type

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: NMSE
Type(s): Service Entrance Head
Connection Type(s): Mast Type

Service entrance caps are used as a connecting point in an overhead service entrance and can be mounted on threaded or unthreaded Rigid or IMC conduit.

  • Slip fit
  • Phenolic insulator with multiple holes
  • Listed for use in wet locations
Model Number
MT1
MT3
MT2
MT4
ABCVolume
2.663.723.14
ABCVolume
ABCVolume
ABCVolume
3.124.574.2
UL: E121487
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Three Piece Coupling

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Coupling
Connection Type(s): Three Piece

Used to connect two lengths of rigid threaded conduit or IMC, when neither conduit can be turned

Model Number
MTPC050
MTPC075
MTPC100
MTPC125
MTPC150
MTPC200
MTPC250
MTPC300
MTPC350
MTPC400
MTPC500
MTPC600
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL,cULus: E155411
CSA,: LR57925,

Standards: UL 514B, CSA C22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

45° Liquid-Tight Connector

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): 45 Degree

Used to terminate and seal liquid tight flexible metal and liquid tight flexible non-metallic type B conduits to either an oil-tight, liquid-tight, rain-tight box, or enclosure

  • Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut
  • Cast from high strength ductile iron and zinc plated
  • Furnished with Sealing Ring
  • With aluminum grounding lug
  • With steel nut
Model Number
MNTY037L
MNTY050L
MNTY075L
MNTY100L
MLTY125L
MLTY150L
MLTY200L
MLTY250L
MLTY300L
MLTY350L
MLTY400L
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 514B, CSA C22.2 No. 18
Other: NEC Article 351
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

One-Hole Strap

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: EMTRigid
Type(s): Strap
Connection Type(s): One-Hole

Used to support rigid conduit or IMC to mounting surface

  • Can be used with clamp backs
  • Cast from high strength malleable iron
    and zinc plated
  • Cast from high strength malleable iron and zinc plated
  • Approved for use with EMT and Rigid/IMC
Model Number
MS037
MS050
MS075
MS100
MS125
MS150
MS200
MS250
MS300
MS350
MS400
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
,cULus: ,E229278
,CSA: ,LR57925

Standards: UL 2239, CSA 22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Squeeze Connector

Material: Malleable Iron
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): Squeeze

Used to terminate flexible metal conduit, armored or metal clad cables to an enclosure or outlet box

  • Assembled with steel locknut and zinc plated steel screws
  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
MSSQ037
MSSQ050
MSSQ075
MSSQ100
MSSQ125
MSSQ150
MSSQ200
MSSQ250
MSSQ300
MSSQ350
MSSQ400
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

45° Insulated Liquid-Tight Connector

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): 45 Degree
Feature(s): Insulated

Used to terminate and seal liquid tight flexible metal and liquid tight flexible non-metallic type B Conduits to either an oil-tight, liquid-tight, rain-tight box, or enclosure

  • Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut
  • Cast from high strength ductile iron and zinc plated
  • Furnished with Sealing Ring
  • With 105° C rated throat insulator
  • Includes steel nut
Model Number
MNTY037I
MNTY050I
MNTY075I
MNTY100I
MLTY125I
MLTY150I
MLTY200I
MLTY250I
MLTY300I
MLTY350I
MLTY400I
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E155411

Standards: UL 514B, CSA C22.2 No. 18
NEMA: NEMA FB-1
Other: NEC Article 351
65!
WARNING:
Risk of reproductive harm from exposure to Bisphenol A (BPA).
See www.P65Warnings.ca.gov
< Products

45° Insulated Liquid-Tight Connector

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): 45 Degree
Feature(s): Insulated

Used to terminate and seal liquid tight flexible metal and liquid tight flexible non-metallic type B conduits to either an oil-tight, liquid-tight, rain-tight box, or enclosure

  • Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut
  • Cast from high strength ductile iron and zinc plated
  • Furnished with Sealing Ring
  • With copper grounding lug
  • With steel nutWith 105° C rated throat insulator
  • With 105° C rated throat insulator,
Model Number
MNTY037IC
MNTY050IC
MNTY075IC
MNTY100IC
MLTY125IC
MLTY150IC
MLTY200IC
MLTY250IC
MLTY300IC
MLTY350IC
MLTY400IC
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 514B, CSA C22.2 No. 18
Other: NEC Article 351
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

45° Insulated Liquid-Tight Connector

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): 45 Degree
Feature(s): Insulated

Used to terminate and seal liquid tight flexible metal and liquid tight flexible non-metallic type B conduits to either an oil-tight, liquid-tight, rain-tight box, or enclosure

  • Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut
  • Cast from high strength ductile iron and zinc plated
  • Furnished with Sealing Ring
  • With aluminum grounding lug
  • With steel nutWith 105° C rated throat insulator
  • With 105° C rated throat insulator,
Model Number
MNTY037IL
MNTY050IL
MNTY075IL
MNTY100IL
MLTY125IL
MLTY150IL
MLTY200IL
MLTY250IL
MLTY300IL
MLTY350IL
MLTY400IL
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 514B, CSA C22.2 No. 18
Other: NEC Article 351
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Straight Liquid-Tight Connector

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): Straight

Used to terminate and seal liquid tight flexible metal and liquid tight flexible non-metallic type B conduits to either an oil-tight, liquid-tight, rain-tight box, or enclosure

  • Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut
  • Cast from high strength ductile iron and zinc plated
  • Furnished with Sealing Ring
  • With aluminum grounding lug
  • With steel nut
Model Number
MNTS037L
MNTS050L
MNTS075L
MNTS100L
MLTS125L
MLTS150L
MLTS200L
MLTS250L
MLTS300L
MLTS350L
MLTS400L
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 514B, CSA C22.2 No. 18
Other: NEC Article 351
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

45° Liquid-Tight Connector

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): 45 Degree

Used to terminate and seal liquid tight flexible metal and liquid tight flexible non-metallic type B Conduits to either an oil-tight, liquid-tight, rain-tight box, or enclosure

  • Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut
  • Cast from high strength ductile iron and zinc plated
  • Furnished with Sealing Ring
  • Includes steel nut
Model Number
MNTY037
MNTY050
MNTY075
MNTY100
MLTY125
MLTY150
MLTY200
MLTY250
MLTY300
MLTY350
MLTY400
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E155411

Standards: UL 514B, CSA C22.2 No. 18
NEMA: NEMA FB-1
Other: NEC Article 351
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

45° Liquid-Tight Connector

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): 45 Degree

Used to terminate and seal liquid tight flexible metal and liquid tight flexible non-metallic type B conduits to either an oil-tight, liquid-tight, rain-tight box, or enclosure

  • Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut
  • Cast from high strength ductile iron and zinc plated
  • Furnished with Sealing Ring
  • With copper grounding lug
  • With steel nut
Model Number
MNTY037C
MNTY050C
MNTY075C
MNTY100C
MLTY125C
MLTY150C
MLTY200C
MLTY250C
MLTY300C
MLTY350C
MLTY400C
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 514B, CSA C22.2 No. 18
Other: NEC Article 351
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Straight Insulated Liquid-Tight Connector

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): Straight
Feature(s): Insulated

Used to terminate and seal liquid tight flexible metal and liquid tight flexible non-metallic type B Conduits to either an oil-tight, liquid-tight, rain-tight box, or enclosure

  • Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut
  • Cast from high strength ductile iron and zinc plated
  • Furnished with Sealing Ring
  • With 105° C rated throat insulator
  • Includes steel nut
Model Number
MNTS037I
MNTS050I
MNTS075I
MNTS100I
MLTS125I
MLTS150I
MLTS200I
MLTS250I
MLTS300I
MLTS350I
MLTS400I
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E155411

Standards: UL 514B, CSA C22.2 No. 18
NEMA: NEMA FB-1
Other: NEC Article 351
65!
WARNING:
Risk of reproductive harm from exposure to Bisphenol A (BPA).
See www.P65Warnings.ca.gov
< Products

Insulated Straight Liquid-Tight Connector

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): Straight
Feature(s): Insulated

Used to terminate and seal liquid tight flexible metal and liquid tight flexible non-metallic type B conduits to either an oil-tight, liquid-tight, rain-tight box, or enclosure

  • Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut
  • Cast from high strength ductile iron and zinc plated
  • Furnished with Sealing Ring
  • With 105° C rated throat insulator
  • With copper grounding lug
  • With steel nut
Model Number
MNTS037IC
MNTS050IC
MNTS075IC
MNTS100IC
MLTS125IC
MLTS150IC
MLTS200IC
MLTS250IC
MLTS300IC
MLTS350IC
MLTS400IC
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 514B, CSA C22.2 No. 18
Other: NEC Article 351
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Straight Liquid-Tight Connector

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): Straight
Feature(s): Insulated

Used to terminate and seal liquid tight flexible metal and liquid tight flexible non-metallic type B conduits to either an oil-tight, liquid-tight, rain-tight box, or enclosure

  • Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut
  • Cast from high strength ductile iron and zinc plated
  • Furnished with Sealing Ring
  • With 105° C rated throat insulator
  • With aluminum grounding lug
  • With steel nut
Model Number
MNTS037IL
MNTS050IL
MNTS075IL
MNTS100IL
MLTS125IL
MLTS150IL
MLTS200IL
MLTS250IL
MLTS300IL
MLTS350IL
MLTS400IL
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 514B, CSA C22.2 No. 18
Other: NEC Article 351
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

90° Liquid-Tight Connector

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): 90 Degree

Used to terminate and seal liquid tight flexible metal and liquid tight flexible non-metallic type B conduits to either an oil-tight, liquid-tight, rain-tight box, or enclosure

  • Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut
  • Cast from high strength ductile iron and zinc plated
  • Furnished with Sealing Ring
  • With aluminum grounding lug
  • With steel nut
Model Number
MNTA037L
MNTA050L
MNTA075L
MNTA100L
MLTA125L
MLTA150L
MLTA200L
MLTA250L
MLTA300L
MLTA350L
MLTA400L
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 514B, CSA C22.2 No. 18
Other: NEC Article 351
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Straight Liquid-Tight Connector

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): Straight

Straight liquid-tight connectors are used to terminate and seal Liquid-Tight Flexible Metal and/or Non-Metallic Type B Conduits to an oil-tight, liquid-tight or rain-tight box or enclosure. Connectors can be used with tapered threaded female entry or unthreaded knockout using the provided sealing washer and locknut.,Used to terminate and seal liquid tight flexible metal and liquid tight flexible non-metallic type B Conduits to either an oil-tight, liquid-tight, rain-tight box, or enclosure

  • Furnished with sealing ring,Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut
  • For Liquid-Tight Flexible Metal and Non-Metallic Type B Conduits,Cast from high strength ductile iron and zinc plated
  • ,Furnished with Sealing Ring
Model Number
MNTS037
MNTS050
MNTS075
MNTS100
MLTS125
MLTS150
MLTS200
MLTS250
MLTS300
MLTS350
MLTS400
ABCVolume
ABCVolume
1.691.140.53
ABCVolume
1.781.380.53
ABCVolume
1.951.610.66
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E155411

Standards: UL 514B, CSA C22.2 No. 18
NEMA: NEMA FB-1
Other: NEC Article 351
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Straight Liquid-Tight Connector

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): Straight

Used to terminate and seal liquid tight flexible metal and liquid tight flexible non-metallic type B conduits to either an oil-tight, liquid-tight, rain-tight box, or enclosure

  • Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut
  • Cast from high strength ductile iron and zinc plated
  • Furnished with Sealing Ring
  • With copper grounding lug
  • With steel nut
Model Number
MNTS037C
MNTS050C
MNTS075C
MNTS100C
MLTS125C
MLTS150C
MLTS200C
MLTS250C
MLTS300C
MLTS350C
MLTS400C
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 514B, CSA C22.2 No. 18
Other: NEC Article 351
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

90° Insulated Liquid-Tight Connector

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): 90 Degree
Feature(s): Insulated

Used to terminate and seal liquid tight flexible metal and liquid tight flexible non-metallic type B Conduits to either an oil-tight, liquid-tight, rain-tight box, or enclosure

  • Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut
  • Cast from high strength ductile iron and zinc plated
  • Furnished with Sealing Ring
  • With 105° C rated throat insulator
  • Includes steel nut
Model Number
MNTA037I
MNTA050I
MNTA075I
MNTA100I
MLTA125I
MLTA150I
MLTA200I
MLTA250I
MLTA300I
MLTA350I
MLTA400I
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E155411

Standards: UL 514B, CSA C22.2 No. 18
NEMA: NEMA FB-1
Other: NEC Article 351
65!
WARNING:
Risk of reproductive harm from exposure to Bisphenol A (BPA).
See www.P65Warnings.ca.gov
< Products

90° Insulated Liquid-Tight Connector

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): 90 Degree
Feature(s): Insulated

Used to terminate and seal liquid tight flexible metal and liquid tight flexible non-metallic type B conduits to either an oil-tight, liquid-tight, rain-tight box, or enclosure

  • Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut
  • Cast from high strength ductile iron and zinc plated
  • Furnished with Sealing Ring
  • With copper grounding lug
  • With steel nutWith 105° C rated throat insulator
  • With 105° C rated throat insulator
Model Number
MNTA037IC
MNTA050IC
MNTA075IC
MNTA100IC
MLTA125IC
MLTA150IC
MLTA200IC
MLTA250IC
MLTA300IC
MLTA350IC
MLTA400IC
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 514B, CSA C22.2 No. 18
Other: NEC Article 351
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

90° Insulated Liquid-Tight Connector

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): 90 Degree
Feature(s): Insulated

Used to terminate and seal liquid tight flexible metal and liquid tight flexible non-metallic type B conduits to either an oil-tight, liquid-tight, rain-tight box, or enclosure

  • Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut
  • Cast from high strength ductile iron and zinc plated
  • Furnished with Sealing Ring
  • With aluminum grounding lug
  • With steel nutWith 105° C rated throat insulator
  • With 105° C rated throat insulator
Model Number
MNTA037IL
MNTA050IL
MNTA075IL
MNTA100IL
MLTA125IL
MLTA150IL
MLTA200IL
MLTA250IL
MLTA300IL
MLTA350IL
MLTA400IL
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 514B, CSA C22.2 No. 18
Other: NEC Article 351
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type X

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): Type X

Used with threaded rigid conduit or IMC for providing access to the interior of a conduit system for pulling, splicing, inspection and maintenance

  • Flat back design for easy mounting close to walls
  • NPT threaded hubs
  • Cast from high strength malleable iron/ductile iron and zinc plated
Model Number
MLX050
MLX075
MLX100
MLX125
MLX150
MLX200
ABCVolume
5.6
ABCVolume
9.5
ABCVolume
15
ABCVolume
33
ABCVolume
36
ABCVolume
75
UL: E121488
CSA: LR57925

Standards: UL 514B, CSA 22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

90° Liquid-Tight Connector

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): 90 Degree

90° liquid-tight connectors are used to terminate and seal Liquid-Tight Flexible Metal and/or
Non-Metallic Type B Conduits at 90° angles to an oil-tight, liquid-tight or rain-tight box or enclosure. Connectors can be used with tapered threaded female entry or unthreaded knockout using the provided sealing washer and locknut.,Used to terminate and seal liquid tight flexible metal and liquid tight flexible non-metallic type B Conduits to either an oil-tight, liquid-tight, rain-tight box, or enclosure

  • Furnished with sealing ring,Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut
  • For Liquid-Tight Flexible Metal and Non-Metallic Type B Conduits,Cast from high strength ductile iron and zinc plated
  • ,Furnished with Sealing Ring
Model Number
MNTA037
MNTA050
MNTA075
MNTA100
MLTA125
MLTA150
MLTA200
MLTA250
MLTA300
MLTA350
MLTA400
ABCVolume
ABCVolume
1.251.130.53
ABCVolume
1.581.310.53
ABCVolume
1.841.640.66
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E155411

Standards: UL 514B, CSA C22.2 No. 18
NEMA: NEMA FB-1
Other: NEC Article 351
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

90° Liquid-Tight Connector

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): 90 Degree

Used to terminate and seal liquid tight flexible metal and liquid tight flexible non-metallic type B conduits to either an oil-tight, liquid-tight, rain-tight box, or enclosure

  • Connectors can be used with tapered thread female entry or unthreaded knock-out using the provided sealing washer and locknut
  • Cast from high strength ductile iron and zinc plated
  • Furnished with Sealing Ring
  • With copper grounding lug
  • With steel nut
Model Number
MNTA037C
MNTA050C
MNTA075C
MNTA100C
MLTA125C
MLTA150C
MLTA200C
MLTA250C
MLTA300C
MLTA350C
MLTA400C
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 514B, CSA C22.2 No. 18
Other: NEC Article 351
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type LL

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): Type LL

Used with threaded rigid conduit or IMC for providing access to the interior of a conduit system for pulling, splicing, inspection and maintenance

  • Flat back design for easy mounting close to walls
  • NPT threaded hubs
  • Cast from high strength malleable iron/ductile iron and zinc plated
Model Number
MLL050
MLL075
MLL100
MLL125
MLL150
MLL200
MLL250
MLL300
MLL350
MLL400
ABCVolume
4.5
ABCVolume
7.5
ABCVolume
12.5
ABCVolume
32.3
ABCVolume
35.3
ABCVolume
73
ABCVolume
138
ABCVolume
170
ABCVolume
300
ABCVolume
328
UL: E121488
CSA: LR57925

Standards: UL 514B, CSA 22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type LR

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): Type LR

Used with threaded rigid conduit or IMC for providing access to the interior of a conduit system for pulling, splicing, inspection and maintenance

  • Flat back design for easy mounting close to walls
  • NPT threaded hubs
  • Cast from high strength malleable iron/ductile iron and zinc plated
Model Number
MLR050
MLR075
MLR100
MLR125
MLR150
MLR200
MLR250
MLR300
MLR350
MLR400
ABCVolume
4.5
ABCVolume
7.5
ABCVolume
12.5
ABCVolume
32.3
ABCVolume
35.3
ABCVolume
73
ABCVolume
138
ABCVolume
170
ABCVolume
300
ABCVolume
328
UL: E121488
CSA: LR57925

Standards: UL 514B, CSA 22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type T

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): Type T

Used with threaded rigid conduit or IMC for providing access to the interior of a conduit system for pulling, splicing, inspection and maintenance

  • Flat back design for easy mounting close to walls
  • NPT threaded hubs
  • Cast from high strength malleable iron/ductile iron and zinc plated
Model Number
MLT050
MLT075
MLT100
MLT125
MLT150
MLT200
MLT250
MLT300
MLT350
MLT400
ABCVolume
6
ABCVolume
9.5
ABCVolume
15
ABCVolume
33
ABCVolume
36
ABCVolume
75
ABCVolume
138
ABCVolume
170
ABCVolume
300
ABCVolume
328
UL: E121488
CSA: LR57925

Standards: UL 514B, CSA 22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

J Clamp

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: AccessoriesEMTRigid
Type(s): J Clamp

Used to attach rigid conduit, IMC, or EMT to steel structures

  • Assembled with square head bolt
  • Cast from high strength malleable iron/ductile iron and zinc plated
Model Number
MJ050
MJ075
MJ100
ABCVolume
ABCVolume
ABCVolume
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type LB

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): Type LB

Used with threaded rigid conduit or IMC for providing access to the interior of a conduit system for pulling, splicing, inspection and maintenance

  • Flat back design for easy mounting close to walls
  • NPT threaded hubs
  • Cast from high strength malleable iron/ductile iron and zinc plated
Model Number
MLB050
MLB075
MLB100
MLB125
MLB150
MLB200
MLB250
MLB300
MLB350
MLB400
ABCVolume
4.5
ABCVolume
7.5
ABCVolume
12.5
ABCVolume
32.3
ABCVolume
35.3
ABCVolume
73
ABCVolume
138
ABCVolume
170
ABCVolume
300
ABCVolume
328
UL: E121488
CSA: LR57925

Standards: UL 514B, CSA 22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type C

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): Threaded
Feature(s): Type C

Used with threaded rigid conduit or IMC for providing access to the interior of a conduit system for pulling, splicing, inspection and maintenance

  • Flat back design for easy mounting close to walls
  • NPT threaded hubs
  • Cast from high strength malleable iron/ductile iron and zinc plated
Model Number
MLC050
MLC075
MLC100
MLC125
MLC150
MLC200
MLC250
MLC300
MLC350
MLC400
ABCVolume
4.5
ABCVolume
7.5
ABCVolume
12.5
ABCVolume
32.3
ABCVolume
35.3
ABCVolume
73
ABCVolume
138
ABCVolume
170
ABCVolume
300
ABCVolume
328
UL: E121488
CSA: LR57925

Standards: UL 514B, CSA 22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Set Screw Grounding Bushing with Copper Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-LugSet Screw
Feature(s): Insulated

Used to terminate rigid conduit or IMC to an enclosure

  • Provided with lay-in style copper lug for easy attachment of grounding wire
  • With 150°C rated insulator
Model Number
MGBILC250Z
MGBILC300Z
MGBILC350Z
MGBILC400Z
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Set Screw Conduit Bushing

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): InsulatingSet Screw
Feature(s): Insulated

Used to terminate rigid conduit or IMC to an enclosure

  • Bushing throat provides a smooth surface to prevent damage to wire during pulling
  • With 150°C rated insulator
Model Number
MGBI050SS
MGBI075SS
MGBI100SS
MGBI125SS
MGBI150SS
MGBI200SS
MGBI250SS
MGBI300SS
MGBI350SS
MGBI400SS
MGBI500SS
MGBI600SS
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA 22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Set Screw Conduit Bushing

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): Set Screw

Used to terminate threaded rigid conduit or IMC to an enclosure

  • With 3 tapped holes
Model Number
MGB050T
MGB075T
MGB100T
MGB125T
MGB150T
MGB200T
MGB250T
MGB300T
MGB350T
MGB400T
MGB500T
MGB600T
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E155411

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Copper Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate rigid conduit or IMC to an enclosure

  • Provided with lay-in style copper lug for easy attachment of grounding wire
  • With 150°C rated insulator
  • With 3 tapped holes
Model Number
MGBILC250T
MGBILC300T
MGBILC350T
MGBILC400T
MGBILC500T
MGBILC600T
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Set Screw Grounding Bushing with Copper Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-LugSet Screw
Feature(s): Insulated

Used to terminate rigid conduit or IMC to an enclosure

  • Provided with lay-in style copper lug for easy attachment of grounding wire
  • With 150°C rated insulator
Model Number
MGBILC050X
MGBILC075X
MGBILC100X
MGBILC125X
MGBILC150X
MGBILC200X
MGBILC250X
MGBILC300X
MGBILC350X
MGBILC400X
MGBILC500X
MGBILC600X
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Set Screw Grounding Bushing with Copper Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-LugSet Screw
Feature(s): Insulated

Used to terminate rigid conduit or IMC to an enclosure

  • Provided with lay-in style copper lug for easy attachment of grounding wire
  • With 150°C rated insulator
Model Number
MGBILC125Y
MGBILC150Y
MGBILC200Y
MGBILC250Y
MGBILC300Y
MGBILC350Y
MGBILC400Y
MGBILC500Y
MGBILC600Y
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Feed-Thru Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): Feed-thruGrounding
Feature(s): Insulated

Used to terminate threaded rigid conduit, or IMC to an enclosure

  • Provided with feed-thru aluminum lug for attaching a grounding wire
  • With 150°C rated insulator
  • With larger lug for greater range of cables
Model Number
MGBILB250S
MGBILB300S
MGBILB350S
MGBILB400S
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 467 & 486A-486B, CSA C22.2 No. 41-13 & CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Copper Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate rigid conduit or IMC to an enclosure

  • Provided with lay-in style copper lug for easy attachment of grounding wire
  • With 150°C rated insulator
Model Number
MGBILC050
MGBILC075
MGBILC100
MGBILC125
MGBILC150
MGBILC200
MGBILC250
MGBILC300
MGBILC350
MGBILC400
MGBILC500
MGBILC600
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Copper Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate rigid conduit or IMC to an enclosure

  • Provided with lay-in style copper lug for easy attachment of grounding wire
  • With 150°C rated insulator
  • With larger lug for greater range of cables
Model Number
MGBILC125S
MGBILC150S
MGBILC200S
MGBILC250S
MGBILC300S
MGBILC350S
MGBILC400S
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate threaded rigid conduit, or IMC to an enclosure

  • Provided with lay-in style aluminum lug for easy attachment of grounding wire
  • With 150°C rated insulator
Model Number
MGBILA125Y
MGBILA150Y
MGBILA200Y
MGBILA250Y
MGBILA300Y
MGBILA350Y
MGBILA400Y
MGBILA500Y
MGBILA600Y
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 467 & 486A-486B, CSA C22.2 No. 41-13 & CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate threaded rigid conduit, or IMC to an enclosure

  • Provided with lay-in style aluminum lug for easy attachment of grounding wire
  • With 150°C rated insulator
Model Number
MGBILA250Z
MGBILA300Z
MGBILA350Z
MGBILA400Z
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 467 & 486A-486B, CSA C22.2 No. 41-13 & CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Feed-Thru Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): Feed-thruGrounding
Feature(s): Insulated

Used to terminate threaded rigid conduit, or IMC to an enclosure

  • Provided with feed-thru aluminum lug for attaching a grounding wire
  • With 150°C rated insulator
Model Number
MGBILB050
MGBILB075
MGBILB100
MGBILB125
MGBILB150
MGBILB200
MGBILB250
MGBILB300
MGBILB350
MGBILB400
MGBILB500
MGBILB600
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus,: E88878,

Standards: UL 467 & 486A-486B, CSA C22.2 No. 41-13 & CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate threaded rigid conduit, or IMC to an enclosure

  • Provided with lay-in style aluminum lug for easy attachment of grounding wire
  • With 150°C rated insulator
  • With larger lug for greater range of cables
Model Number
MGBILA125S
MGBILA150S
MGBILA200S
MGBILA250S
MGBILA300S
MGBILA350S
MGBILA400S
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 467 & 486A-486B, CSA C22.2 No. 41-13 & CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate threaded rigid conduit, or IMC to an enclosure

  • Provided with lay-in style aluminum lug for easy attachment of grounding wire
  • With 150°C rated insulator
  • With 3 tapped holes
Model Number
MGBILA250T
MGBILA300T
MGBILA350T
MGBILA400T
MGBILA500T
MGBILA600T
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 467 & 486A-486B, CSA C22.2 No. 41-13 & CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate threaded rigid conduit, or IMC to an enclosure

  • Provided with lay-in style aluminum lug for easy attachment of grounding wire
  • With 150°C rated insulator
Model Number
MGBILA050X
MGBILA075X
MGBILA100X
MGBILA125X
MGBILA150X
MGBILA200X
MGBILA250X
MGBILA300X
MGBILA350X
MGBILA400X
MGBILA500X
MGBILA600X
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 467 & 486A-486B, CSA C22.2 No. 41-13 & CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Set Screw Conduit Bushing

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): InsulatingSet Screw
Feature(s): Insulated

Used to terminate rigid conduit or IMC to an enclosure

  • Bushing throat provides a smooth surface to prevent damage to wire during pulling
  • With 105°C rated insulator
Model Number
MGBG050SS
MGBG075SS
MGBG100SS
MGBG125SS
MGBG150SS
MGBG200SS
MGBG250SS
MGBG300SS
MGBG350SS
MGBG400SS
MGBG500SS
MGBG600SS
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA 22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Conduit Bushing

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): Insulating
Feature(s): Insulated

Used to terminate rigid conduit or IMC to an enclosure

  • Bushing throat provides a smooth surface to prevent damage to wire during pulling
  • With 150°C rated insulator
Model Number
MGBI050
MGBI075
MGBI100
MGBI125
MGBI150
MGBI200
MGBI250
MGBI300
MGBI350
MGBI400
MGBI500
MGBI600
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA 22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate threaded rigid conduit, or IMC to an enclosure

  • Provided with lay-in style aluminum lug for easy attachment of grounding wire
  • With 150°C rated insulator
Model Number
MGBILA050
MGBILA075
MGBILA100
MGBILA125
MGBILA150
MGBILA200
MGBILA250
MGBILA300
MGBILA350
MGBILA400
MGBILA500
MGBILA600
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 467 & 486A-486B, CSA C22.2 No. 41-13 & CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Set Screw Grounding Bushing with Copper Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-LugSet Screw
Feature(s): Insulated

Used to terminate rigid conduit or IMC to an enclosure

  • Provided with lay-in style copper lug for easy attachment of grounding wire
  • With 105°C rated insulator
Model Number
MGBGLC050X
MGBGLC075X
MGBGLC100X
MGBGLC125X
MGBGLC150X
MGBGLC200X
MGBGLC250X
MGBGLC300X
MGBGLC350X
MGBGLC400X
MGBGLC500X
MGBGLC600X
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Set Screw Grounding Bushing with Copper Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-LugSet Screw
Feature(s): Insulated

Used to terminate rigid conduit or IMC to an enclosure

  • Provided with lay-in style copper lug for easy attachment of grounding wire
  • With 105°C rated insulator
Model Number
MGBGLC125Y
MGBGLC150Y
MGBGLC200Y
MGBGLC250Y
MGBGLC300Y
MGBGLC350Y
MGBGLC400Y
MGBGLC500Y
MGBGLC600Y
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Set Screw Grounding Bushing with Copper Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-LugSet Screw
Feature(s): Insulated

Used to terminate rigid conduit or IMC to an enclosure

  • Provided with lay-in style copper lug for easy attachment of grounding wire
  • With 105°C rated insulator
Model Number
MGBGLC250Z
MGBGLC300Z
MGBGLC350Z
MGBGLC400Z
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Copper Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate rigid conduit or IMC to an enclosure

  • Provided with lay-in style copper lug for easy attachment of grounding wire
  • With 105°C rated insulator
Model Number
MGBGLC050
MGBGLC075
MGBGLC100
MGBGLC125
MGBGLC150
MGBGLC200
MGBGLC250
MGBGLC300
MGBGLC350
MGBGLC400
MGBGLC500
MGBGLC600
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Copper Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate rigid conduit or IMC to an enclosure

  • Provided with lay-in style copper lug for easy attachment of grounding wire
  • With 105°C rated insulator
  • With larger lug for greater range of cables
Model Number
MGBGLC125S
MGBGLC150S
MGBGLC200S
MGBGLC250S
MGBGLC300S
MGBGLC350S
MGBGLC400S
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Copper Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate rigid conduit or IMC to an enclosure

  • Provided with lay-in style copper lug for easy attachment of grounding wire
  • With 105°C rated insulator
  • With 3 tapped holes
Model Number
MGBGLC250T
MGBGLC300T
MGBGLC350T
MGBGLC400T
MGBGLC500T
MGBGLC600T
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate threaded rigid conduit, or IMC to an enclosure

  • Provided with lay-in style aluminum lug for easy attachment of grounding wire
  • With 105°C rated insulator
Model Number
MGBGLA050X
MGBGLA075X
MGBGLA100X
MGBGLA125X
MGBGLA150X
MGBGLA200X
MGBGLA250X
MGBGLA300X
MGBGLA350X
MGBGLA400X
MGBGLA500X
MGBGLA600X
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 467 & 486A-486B, CSA C22.2 No. 41-13 & CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate threaded rigid conduit, or IMC to an enclosure

  • Provided with lay-in style aluminum lug for easy attachment of grounding wire
  • With 105°C rated insulator
Model Number
MGBGLA125Y
MGBGLA150Y
MGBGLA200Y
MGBGLA250Y
MGBGLA300Y
MGBGLA350Y
MGBGLA400Y
MGBGLA500Y
MGBGLA600Y
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 467 & 486A-486B, CSA C22.2 No. 41-13 & CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate threaded rigid conduit, or IMC to an enclosure

  • Provided with lay-in style aluminum lug for easy attachment of grounding wire
  • With 105°C rated insulator
Model Number
MGBGLA250Z
MGBGLA300Z
MGBGLA350Z
MGBGLA400Z
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 467 & 486A-486B, CSA C22.2 No. 41-13 & CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate threaded rigid conduit, or IMC to an enclosure

  • Provided with lay-in style aluminum lug for easy attachment of grounding wire
  • With 105°C rated insulator
Model Number
MGBGLA050
MGBGLA075
MGBGLA100
MGBGLA125
MGBGLA150
MGBGLA150
MGBGLA200
MGBGLA250
MGBGLA300
MGBGLA350
MGBGLA400
MGBGLA500
MGBGLA600
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 467 & 486A-486B, CSA C22.2 No. 41-13 & CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate threaded rigid conduit, or IMC to an enclosure

  • Provided with lay-in style aluminum lug for easy attachment of grounding wire
  • With 105°C rated insulator
  • With larger lug for greater range of cables
Model Number
MGBGLA125S
MGBGLA200S
MGBGLA250S
MGBGLA300S
MGBGLA350S
MGBGLA400S
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 467 & 486A-486B, CSA C22.2 No. 41-13 & CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Lay-in-Lug

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate threaded rigid conduit, or IMC to an enclosure

  • Provided with lay-in style aluminum lug for easy attachment of grounding wire
  • With 105°C rated insulator
  • With 3 tapped holes
Model Number
MGBGLA250T
MGBGLA300T
MGBGLA350T
MGBGLA400T
MGBGLA500T
MGBGLA600T
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 467 & 486A-486B, CSA C22.2 No. 41-13 & CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Floor Flange

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Floor Flange

Used to secure rigid conduit or IMC to the floor

Model Number
MFF050
MFF075
MFF100
MFF125
MFF150
MFF200
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Bushing

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing

Used to terminate rigid conduit or IMC to an enclosure

Model Number
MGB050
MGB075
MGB100
MGB125
MGB150
MGB200
MGB250
MGB300
MGB350
MGB400
MGB500
MGB600
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA 22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Conduit Bushing

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): Insulating
Feature(s): Insulated

Used to terminate rigid conduit or IMC to an enclosure

  • Bushing throat provides a smooth surface to prevent damage to wire during pulling
  • With 105°C rated insulator
Model Number
MGBG050
MGBG075
MGBG100
MGBG125
MGBG150
MGBG200
MGBG250
MGBG300
MGBG350
MGBG400
MGBG500
MGBG600
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA 22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Support

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Accessories
Type(s): Conduit Support

Used to support and secure rigid conduit, IMC, or EMT to a mounting surface,Conduit supports are used to secure conduit to the outside surface of a building.

  • Cast from high strength malleable iron/ ductile iron and zinc plated,Lag Screw Type
  • With 1/2″ x 10″ threaded rod,For Rigid, IMC or EMT conduit,With 5/8″ x 14″ threaded rod
Model Number
MCS200
MCS200L
MCS250
MCS250L
MCS300
MCS350
MCS400
ABCVolume
ABCVolume
5.272.44.27
ABCVolume
ABCVolume
5.682.44.86
ABCVolume
ABCVolume
ABCVolume
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Support

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Accessories
Type(s): Conduit Support

Used to support and secure rigid conduit, IMC, or EMT to a mounting surface

  • Cast from high strength malleable iron/ ductile iron and zinc plated
  • Clamp only
Model Number
MCS200U
MCS250U
MCS300U
MCS350U
MCS400U
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

90˚ Duplex Squeeze Connector

Material: Malleable Iron
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): 90 DegreeDuplexSqueeze

Used to terminate flexible metal conduit, armored or metal clad cables to an enclosure or outlet box

  • Assembled with steel locknut and zinc plated steel screws
  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
MDA037
ABCVolume
Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Clamp Back

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Rigid
Type(s): Clamp Back

Provide space between conduit and mounting surface

  • Used with one hole straps to support rigid conduit or IMC
  • Cast from high strength malleable iron
    and zinc plated
Model Number
MCB050
MCB075
MCB100
MCB125
MCB150
MCB200
MCB250
MCB300
MCB350
MCB400
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E229278
CSA: LR57925

Standards: UL 2239, CSA 22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Nipple

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Nipple

Used with locknut to serve as a short raceway between enclosures

Model Number
MCN050
MCN075
MCN100
MCN125
MCN150
MCN200
MCN250
MCN300
MCN350
MCN400
MCN500
MCN600
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Conduit Nipple

Material: Malleable Iron
Category: Fittings
Sub Category: Rigid
Type(s): Nipple
Feature(s): Insulated

Used with locknut to serve as a short raceway between enclosures

  • With 90° C rated insulated throat
Model Number
MCN050I
MCN075I
MCN100I
MCN125I
MCN150I
MCN200I
MCN250I
MCN300I
MCN350I
MCN400I
MCN500I
MCN600I
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of reproductive harm from exposure to Bisphenol A (BPA).
See www.P65Warnings.ca.gov
< Products

Beam Clamp

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Accessories
Type(s): Beam Clamp

Used to attach electrical hardware to steel structures

  • Assembled with square head bolt
  • Cast from high strength malleable iron/ductile iron and zinc plated
Model Number
BMB3
ABCVolume
UL: E229278
CSA: LR57925

Standards: UL 2239, CSA C22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Beam Clamp

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Accessories
Type(s): Beam Clamp

Used to attach electrical hardware to steel structures

  • Assembled with square head bolt
  • Cast from high strength malleable iron/ductile iron and zinc plated
Model Number
MB4
ABCVolume
UL: E229278
CSA: LR57925

Standards: UL 2239, CSA C22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Beam Clamp

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Accessories
Type(s): Beam Clamp

Used to attach electrical hardware to steel structures

  • Assembled with square head bolt
  • Cast from high strength malleable iron/ductile iron and zinc plated
Model Number
BMB4
ABCVolume
UL: E229278
CSA: LR57925

Standards: UL 2239, CSA C22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Beam Clamp

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Accessories
Type(s): Beam Clamp

Used to attach electrical hardware to steel structures

  • Assembled with square head bolt
  • Cast from high strength malleable iron/ductile iron and zinc plated
Model Number
MB1BS
ABCVolume
cULus: E229278
CSA: LR57925

Standards: UL 2239, CSA C22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Beam Clamp

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Accessories
Type(s): Beam Clamp

Used to attach electrical hardware to steel structures

  • Assembled with square head bolt
  • Cast from high strength malleable iron/ductile iron and zinc plated
Model Number
MB2
ABCVolume
UL: E229278
CSA: LR57925

Standards: UL 2239, CSA C22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Beam Clamp

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Accessories
Type(s): Beam Clamp

Used to attach electrical hardware to steel structures

  • Assembled with square head bolt
  • Cast from high strength malleable iron/ductile iron and zinc plated
Model Number
MB3
ABCVolume
UL: E229278
CSA: LR57925

Standards: UL 2239, CSA C22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Beam Clamp

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Accessories
Type(s): Beam Clamp

Used to attach electrical hardware to steel structures

  • Assembled with square head bolt
  • Cast from high strength malleable iron/ductile iron and zinc plated
Model Number
MB1
ABCVolume
UL: E229278
CSA: LR57925

Standards: UL 2239, CSA C22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Beam Clamp

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Accessories
Type(s): Beam Clamp

Beam clamps are used on a beam, girder or other similar structure to provide a mounting base for conduit hangers.

  • Beam thickness 1/8″ – 1/2″
  • Threaded hole 1/4″ – 20
Model Number
MB1S
ABCVolume
1.31.281
cULus: E229278
CSA: LR57925

Standards: UL 2239, CSA C22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Beam Clamp

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Accessories
Type(s): Beam Clamp

Used to attach electrical hardware to steel structures

  • Assembled with square head bolt
  • Cast from high strength malleable iron/ductile iron and zinc plated
Model Number
MB1B
ABCVolume
UL: E229278
CSA: LR57925

Standards: UL 2239, CSA C22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated 90˚ Squeeze Connector

Material: Malleable Iron
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): 90 DegreeSqueeze
Feature(s): Insulated

Used to terminate flexible metal conduit, armored or metal clad cables to an enclosure or outlet box

  • Assembled with steel locknut and zinc plated steel screws
  • 90° C rated throat insulator
  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
MASQ037I
MASQ050I
MASQ075I
MASQ100I
MASQ125I
MASQ150I
MASQ200I
MASQ250I
MASQ300I
MASQ350I
MASQ400I
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Beam Clamp

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Accessories
Type(s): Beam Clamp

Used to attach electrical hardware to steel structures

  • Assembled with square head bolt
  • Cast from high strength malleable iron/ductile iron and zinc plated
Model Number
MB1A
ABCVolume
UL: E229278
CSA: LR57925

Standards: UL 2239, CSA C22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Beam Clamp

Material: Zinc-Plated Iron
Category: Fittings
Sub Category: Accessories
Type(s): Beam Clamp

Used to attach electrical hardware to steel structures

  • Assembled with square head bolt
  • Cast from high strength malleable iron/ductile iron and zinc plated
Model Number
MB1AS
ABCVolume
cULus: E229278
CSA: LR57925

Standards: UL 2239, CSA C22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Set Screw Conduit Body – Type T

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): Conduit Body
Connection Type(s): 90 DegreeSet Screw
Feature(s): Type T

Used with EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Set screw hubs to accommodate EMT
  • Cast from high strength corrosion and weather resistant aluminum alloy
  • Includes rubber gasket & stamped cover
Model Number
LTSS050AN
LTSS075AN
LTSS100AN
LTSS125AN
LTSS150AN
LTSS200AN
LTSS250AN
LTSS300AN
LTSS350AN
LTSS400AN
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
33.1
ABCVolume
33.1
ABCVolume
67
ABCVolume
149
ABCVolume
175
ABCVolume
298
ABCVolume
300
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Set Screw Conduit Body – Type T

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): Conduit Body
Connection Type(s): 90 DegreeSet Screw
Feature(s): Type T

Used with EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Set screw hubs to accommodate EMT
  • Cast from high strength corrosion and weather resistant aluminum alloy
  • Includes fiber gasket & die-cast cover
Model Number
LTSS050CG
LTSS075CG
LTSS100CG
LTSS125CG
LTSS150CG
LTSS200CG
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
33.1
ABCVolume
33.1
ABCVolume
67
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

90˚ Squeeze Connector

Material: Malleable Iron
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): 90 DegreeSqueeze

Used to terminate flexible metal conduit, armored or metal clad cables to an enclosure or outlet box

  • Assembled with steel locknut and zinc plated steel screws
  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
MASQ037
MASQ050
MASQ075
MASQ100
MASQ125
MASQ150
MASQ200
MASQ250
MASQ300
MASQ350
MASQ400
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Straight Liquid-Tight Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): Straight

Straight liquid-tight connectors are used to terminate and seal Liquid-Tight Flexible Metal and/or Non-Metallic Type B Conduits to an oil-tight, liquid-tight or rain-tight box or enclosure. Connectors can be used with tapered threaded female entry or unthreaded knockout using the provided sealing washer and locknut.

  • Furnished with sealing ring
  • For Liquid-Tight Flexible Metal and Non-Metallic Type B Conduits
  • Locknut not included
Model Number
LTS037
LTS050
LTS075
LTS075U
LTS100
LTS125
LTS150
LTS200
LTS250
LTS300
LTS350
LTS400
ABCVolume
ABCVolume
1.371.220.51
ABCVolume
1.451.430.51
ABCVolume
ABCVolume
1.781.750.68
ABCVolume
1.982.230.68
ABCVolume
1.972.480.66
ABCVolume
1.952.980.66
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Straight Insulated Liquid-Tight Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): Straight
Feature(s): Insulated

Used to terminate and seal liquid-tight flexible metal and non-metallic type B conduit to a box or enclosure

  • Connectors can be used with tapered female entry or unthreaded knock out using the provided sealing washer and locknut,Connectors can be used with tapered female entry or unthreaded knock out using the provided sealing washer
  • Cast from high strength zinc alloy
  • With 90° C rated throat insulators
  • Locknut not included
Model Number
LTS037I
LTS050I
LTS075I
LTS100I
LTS100IU
LTS125I
LTS125IU
LTS150I
LTS200I
LTS250I
LTS300I
LTS350I
LTS400I
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Set Screw Conduit Body – Type T

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): Conduit Body
Connection Type(s): 90 DegreeSet Screw
Feature(s): Type T

Used with EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Set screw hubs to accommodate EMT
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LTSS050
LTSS075
LTSS100
LTSS125
LTSS150
LTSS200
LTSS250
LTSS300
LTSS350
LTSS400
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
33.1
ABCVolume
33.1
ABCVolume
67
ABCVolume
149
ABCVolume
175
ABCVolume
298
ABCVolume
300
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Combination Conduit Body – Type T

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMTRigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeCombinationSet ScrewThreaded
Feature(s): Type T

Used with threaded rigid conduit, IMC or EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LTC050
LTC075
LTC100
LTC125
LTC150
LTC200
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
33.1
ABCVolume
33.1
ABCVolume
67
UL: E121488
CSA: LR57925

Standards: UL 514A & 514B, CSA C22.2 No. 18.1-13 & C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Combination Conduit Body – Type T

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMTRigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeCombinationSet ScrewThreaded
Feature(s): Type T

Used with threaded rigid conduit, IMC or EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LTC050AN
LTC075AN
LTC100AN
LTC125AN
LTC150AN
LTC200AN
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
33.1
ABCVolume
33.1
ABCVolume
67
UL: E121488
CSA: LR57925

Standards: UL 514A & 514B, CSA C22.2 No. 18.1-13 & C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type T

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): Type T

Used with threaded rigid conduit or IMC for providing access to the interior of a conduit system for pulling, splicing, inspection and maintenance

  • Flat back design for easy mounting close to walls
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LT050CG
LT075CG
LT100CG
LT125CG
LT150CG
LT200CG
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
33.1
ABCVolume
33.1
ABCVolume
67
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

90° Liquid-Tight Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): 90 Degree

90° liquid-tight connectors are used to terminate and seal Liquid-Tight Flexible Metal and/or
Non-Metallic Type B Conduits at 90° angles to an oil-tight, liquid-tight or rain-tight box or enclosure. Connectors can be used with tapered threaded female entry or unthreaded knockout using the provided sealing washer and locknut.

  • Furnished with sealing ring
  • For Liquid-Tight Flexible Metal and Non-Metallic Type B Conduits
  • Locknut not included
Model Number
LTA037
LTA050
LTA075
LTA075U
LTA100
LTA125
LTA150
LTA200
LTA250
LTA300
LTA350
LTA400
ABCVolume
ABCVolume
1.461.120.48
ABCVolume
1.61.370.56
ABCVolume
ABCVolume
2.371.660.72
ABCVolume
2.312.130.67
ABCVolume
2.52.420.67
ABCVolume
2.82.940.67
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

90° Insulated Liquid-Tight Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Liquid-Tight
Type(s): Connector
Connection Type(s): 90 Degree
Feature(s): Insulated

Used to terminate and seal liquid-tight flexible metal and non-metallic type B conduit to a box or enclosure at a 90° angle

  • Connectors can be used with tapered female entry or unthreaded knock out using the provided sealing washer and locknut
  • With 90° C rated throat insulator
  • Cast from high strength zinc alloy
Model Number
LTA037I
LTA050I
LTA075I
LTA100I
LTA125I
LTA150I
LTA200I
LTA250I
LTA300I
LTA350I
LTA400I
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type T

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): Type T

Conduit bodies are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction.

  • Flat back design for easy mounting close to walls
  • Assembled with removable cover and gasket
  • Stamped aluminum cover
  • Rubber gasket
Model Number
LT050AN
LT075AN
LT100AN
LT125AN
LT150AN
LT200AN
LT250AN
LT300AN
LT350AN
LT400AN
ABCVolume
4.42.11.64.35
ABCVolume
5.52.31.97.3
ABCVolume
6.221.752.0712.2
ABCVolume
8.272.482.8433.1
ABCVolume
8.272.482.8433.1
ABCVolume
10.243.133.5867
ABCVolume
149
ABCVolume
175
ABCVolume
298
ABCVolume
300
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Set Screw Conduit Body – Type LR

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): Conduit Body
Connection Type(s): 90 DegreeSet Screw
Feature(s): Type LR

Used with EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Set screw hubs to accommodate EMT
  • Cast from high strength corrosion and weather resistant aluminum alloy
  • Includes rubber gasket & stamped cover
Model Number
LRSS050AN
LRSS075AN
LRSS100AN
LRSS125AN
LRSS150AN
LRSS200AN
LRSS250AN
LRSS300AN
LRSS350AN
LRSS400AN
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
35.8
ABCVolume
35.1
ABCVolume
69.7
ABCVolume
158
ABCVolume
186
ABCVolume
306
ABCVolume
308
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Set Screw Conduit Body – Type LR

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): Conduit Body
Connection Type(s): 90 DegreeSet Screw
Feature(s): Type LR

Used with EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Set screw hubs to accommodate EMT
  • Cast from high strength corrosion and weather resistant aluminum alloy
  • Includes fiber gasket & die-cast cover
Model Number
LRSS050CG
LRSS075CG
LRSS100CG
LRSS125CG
LRSS150CG
LRSS200CG
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
35.8
ABCVolume
35.1
ABCVolume
69.7
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type T

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): Type T

Used with threaded rigid conduit or IMC for providing access to the interior of a conduit system for pulling, splicing, inspection and maintenance

  • Flat back design for easy mounting close to walls
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LT050
LT075
LT100
LT125
LT150
LT200
LT250
LT300
LT350
LT400
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
33.1
ABCVolume
33.1
ABCVolume
67
ABCVolume
149
ABCVolume
175
ABCVolume
298
ABCVolume
300
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Combination Conduit Body – Type LR

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMTRigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeCombinationSet ScrewThreaded
Feature(s): Type LR

Used with threaded rigid conduit, IMC or EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LRC050AN
LRC075AN
LRC100AN
LRC125AN
LRC150AN
LRC200AN
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
35.8
ABCVolume
35.1
ABCVolume
69.7
UL: E121488
CSA: LR57925

Standards: UL 514A & 514B, CSA C22.2 No. 18.1-13 & C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type LR

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): Type LR

Used with threaded rigid conduit or IMC for providing access to the interior of a conduit system for pulling, splicing, inspection and maintenance

  • Flat back design for easy mounting close to walls
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LR050CG
LR075CG
LR100CG
LR125CG
LR150CG
LR200CG
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
35.8
ABCVolume
35.1
ABCVolume
69.7
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Set Screw Conduit Body – Type LR

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): Conduit Body
Connection Type(s): 90 DegreeSet Screw
Feature(s): Type LR

Used with EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Set screw hubs to accommodate EMT
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LRSS050
LRSS075
LRSS100
LRSS125
LRSS150
LRSS200
LRSS250
LRSS300
LRSS350
LRSS400
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
35.8
ABCVolume
35.1
ABCVolume
69.7
ABCVolume
158
ABCVolume
186
ABCVolume
306
ABCVolume
308
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type LR

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): Type LR

Used with threaded rigid conduit or IMC for providing access to the interior of a conduit system for pulling, splicing, inspection and maintenance

  • Flat back design for easy mounting close to walls
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LR050
LR075
LR100
LR125
LR150
LR200
LR250
LR300
LR350
LR400
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
35.8
ABCVolume
35.1
ABCVolume
69.7
ABCVolume
158
ABCVolume
186
ABCVolume
306
ABCVolume
308
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type LR

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): Type LR

Conduit bodies are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction.,Used with threaded rigid conduit or IMC for providing access to the interior of a conduit system for pulling, splicing, inspection and maintenance

  • Flat back design for easy mounting close to walls
  • Assembled with removable cover and gasket,Cast from high strength corrosion and weather resistant aluminum alloy
  • Stamped aluminum cover,
  • Rubber gasket,
Model Number
LR050AN
LR075AN
LR100AN
LR125AN
LR150AN
LR200AN
LR250AN
LR300AN
LR350AN
LR400AN
ABCVolume
4.42.11.64.35
ABCVolume
5.12.31.97.3
ABCVolume
5.81.752.0712.2
ABCVolume
7.762.482.8435.8
ABCVolume
7.762.482.8435.1
ABCVolume
9.843.133.5969.7
ABCVolume
158
ABCVolume
186
ABCVolume
306
ABCVolume
308
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Combination Conduit Body – Type LR

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMTRigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeCombinationSet ScrewThreaded
Feature(s): Type LR

Used with threaded rigid conduit, IMC or EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LRC050
LRC075
LRC100
LRC125
LRC150
LRC200
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
35.8
ABCVolume
35.1
ABCVolume
69.7
UL: E121488
CSA: LR57925

Standards: UL 514A & 514B, CSA C22.2 No. 18.1-13 & C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Set Screw Conduit Body – Type LL

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): Conduit Body
Connection Type(s): 90 DegreeSet Screw
Feature(s): Type LL

Used with EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Set screw hubs to accommodate EMT
  • Cast from high strength corrosion and weather resistant aluminum alloy
  • Includes rubber gasket & stamped cover
Model Number
LLSS050AN
LLSS075AN
LLSS100AN
LLSS125AN
LLSS150AN
LLSS200AN
LLSS250AN
LLSS300AN
LLSS350AN
LLSS400AN
ABCVolume
4.3
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
35.4
ABCVolume
35.6
ABCVolume
69.7
ABCVolume
158
ABCVolume
186
ABCVolume
306
ABCVolume
308
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Set Screw Conduit Body – Type LL

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): Conduit Body
Connection Type(s): 90 DegreeSet Screw
Feature(s): Type LL

Used with EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Set screw hubs to accommodate EMT
  • Cast from high strength corrosion and weather resistant aluminum alloy
  • Includes fiber gasket & die-cast cover
Model Number
LLSS050CG
LLSS075CG
LLSS100CG
LLSS125CG
LLSS150CG
LLSS200CG
ABCVolume
4.3
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
35.4
ABCVolume
35.6
ABCVolume
69.7
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Zinc Die-Cast Locknuts

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Locknut

Used for securing rigid IMC conduits and other threaded connectors to outlet boxes or enclosures

  • Designed with highly effective cast threads
  • Serrations provided on both sides for improved grip
Model Number
LNC050
LNC075
LNC100
LNC125
LNC150
LNC200
LNC250
LNC300
LNC350
LNC400
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Combination Conduit Body – Type LL

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMTRigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeCombinationSet ScrewThreaded
Feature(s): Type LL

Used with threaded rigid conduit, IMC or EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LLC050AN
LLC075AN
LLC100AN
LLC125AN
LLC150AN
LLC200AN
ABCVolume
4.3
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
35.4
ABCVolume
35.6
ABCVolume
69.7
UL: E121488
CSA: LR57925

Standards: UL 514A & 514B, CSA C22.2 No. 18.1-13 & C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type LL

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): Type LL

Used with threaded rigid conduit or IMC for providing access to the interior of a conduit system for pulling, splicing, inspection and maintenance

  • Flat back design for easy mounting close to walls
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LL050CG
LL075CG
LL100CG
LL125CG
LL150CG
LL200CG
ABCVolume
4.3
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
35.4
ABCVolume
35.6
ABCVolume
69.7
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Set Screw Conduit Body – Type LL

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): Conduit Body
Connection Type(s): 90 DegreeSet Screw
Feature(s): Type LL

Used with EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Set screw hubs to accommodate EMT
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LLSS050
LLSS075
LLSS100
LLSS125
LLSS150
LLSS200
LLSS250
LLSS300
LLSS350
LLSS400
ABCVolume
4.3
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
35.4
ABCVolume
35.6
ABCVolume
69.7
ABCVolume
158
ABCVolume
186
ABCVolume
306
ABCVolume
308
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type LL

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): Type LL

Used with threaded rigid conduit or IMC for providing access to the interior of a conduit system for pulling, splicing, inspection and maintenance

  • Flat back design for easy mounting close to walls
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LL050
LL075
LL100
LL125
LL150
LL200
LL250
LL300
LL350
LL400
ABCVolume
4.3
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
35.4
ABCVolume
35.6
ABCVolume
69.7
ABCVolume
158
ABCVolume
186
ABCVolume
306
ABCVolume
308
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type LL

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): Type LL

Conduit bodies are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction.

  • Flat back design for easy mounting close to walls
  • Assembled with removable cover and gasket
  • Stamped aluminum cover
  • Rubber gasket
Model Number
LL050AN
LL075AN
LL100AN
LL125AN
LL150AN
LL200AN
LL250AN
LL300AN
LL350AN
LL400AN
ABCVolume
4.42.11.64.3
ABCVolume
5.12.31.97.3
ABCVolume
5.81.752.0712.2
ABCVolume
7.762.482.8435.4
ABCVolume
7.762.482.8435.6
ABCVolume
9.843.133.5969.7
ABCVolume
158
ABCVolume
186
ABCVolume
306
ABCVolume
308
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Combination Conduit Body – Type LL

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMTRigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeCombinationSet ScrewThreaded
Feature(s): Type LL

Used with threaded rigid conduit, IMC or EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LLC050
LLC075
LLC100
LLC125
LLC150
LLC200
ABCVolume
4.3
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
35.4
ABCVolume
35.6
ABCVolume
69.7
UL: E121488
CSA: LR57925

Standards: UL 514A & 514B, CSA C22.2 No. 18.1-13 & C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Hub

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Hub

Used with grounding pipe clamps to connect rigid conduit to water pipe for grounding

  • Cast from high strength, highly conductive copper alloy
  • Zinc plated steel hardware
Model Number
LH1
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Hub

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Hub

Used with grounding pipe clamps to connect rigid conduit to water pipe for grounding

  • Cast from high strength, highly conductive copper alloy
  • Zinc plated steel hardware
Model Number
LH2
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Hub

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Hub

Used with grounding pipe clamps to connect rigid conduit to water pipe for grounding

  • Cast from high strength, highly conductive copper alloy
  • Zinc plated steel hardware
Model Number
LH3
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Set Screw Conduit Body – Type C

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): Conduit Body
Connection Type(s): Set Screw
Feature(s): Type C

Used with EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Set screw hubs to accommodate EMT
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LCSS050
LCSS075
LCSS100
LCSS125
LCSS150
LCSS200
LCSS250
LCSS300
LCSS350
LCSS400
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
33.4
ABCVolume
33.5
ABCVolume
69.5
ABCVolume
159
ABCVolume
188
ABCVolume
307
ABCVolume
309
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Set Screw Conduit Body – Type C

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): Conduit Body
Connection Type(s): Set Screw
Feature(s): Type C

Used with EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Set screw hubs to accommodate EMT
  • Cast from high strength corrosion and weather resistant aluminum alloy
  • Includes rubber gasket & stamped cover
Model Number
LCSS050AN
LCSS075AN
LCSS100AN
LCSS125AN
LCSS150AN
LCSS200AN
LCSS250AN
LCSS300AN
LCSS350AN
LCSS400AN
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
33.4
ABCVolume
33.5
ABCVolume
69.5
ABCVolume
159
ABCVolume
188
ABCVolume
307
ABCVolume
309
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Set Screw Conduit Body – Type C

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): Conduit Body
Connection Type(s): Set Screw
Feature(s): Type C

Used with EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Set screw hubs to accommodate EMT
  • Cast from high strength corrosion and weather resistant aluminum alloy
  • Includes fiber gasket & die-cast cover
Model Number
LCSS050CG
LCSS075CG
LCSS100CG
LCSS125CG
LCSS150CG
LCSS200CG
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
33.4
ABCVolume
33.5
ABCVolume
69.5
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Combination Conduit Body – Type C

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMTRigid
Type(s): Conduit Body
Connection Type(s): CombinationSet ScrewThreaded
Feature(s): Type C

Used with threaded rigid conduit, IMC or EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LCC050
LCC075
LCC100
LCC125
LCC150
LCC200
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
33.4
ABCVolume
33.5
ABCVolume
69.5
UL: E121488
CSA: LR57925

Standards: UL 514A & 514B, CSA C22.2 No. 18.1-13 & C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Combination Conduit Body – Type C

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMTRigid
Type(s): Conduit Body
Connection Type(s): CombinationSet ScrewThreaded
Feature(s): Type C

Used with threaded rigid conduit, IMC or EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LCC050AN
LCC075AN
LCC100AN
LCC125AN
LCC150AN
LCC200AN
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
33.4
ABCVolume
33.5
ABCVolume
69.5
UL: E121488
CSA: LR57925

Standards: UL 514A & 514B, CSA C22.2 No. 18.1-13 & C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type C

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): Threaded
Feature(s): Type C

Used with threaded rigid conduit or IMC for providing access to the interior of a conduit system for pulling, splicing, inspection and maintenance

  • Flat back design for easy mounting close to walls
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LC050CG
LC075CG
LC100CG
LC125CG
LC150CG
LC200CG
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
33.4
ABCVolume
33.5
ABCVolume
69.5
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Set Screw Conduit Body – Type LB

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): Conduit Body
Connection Type(s): 90 DegreeSet Screw
Feature(s): Type LB

Used with EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Set screw hubs to accommodate EMT
  • Cast from high strength corrosion and weather resistant aluminum alloy
  • Includes fiber gasket & die-cast cover
Model Number
LBSS050CG
LBSS075CG
LBSS100CG
LBSS125CG
LBSS150CG
LBSS200CG
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
32.3
ABCVolume
33.8
ABCVolume
71.2
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type C

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): Threaded
Feature(s): Type C

Used with threaded rigid conduit or IMC for providing access to the interior of a conduit system for pulling, splicing, inspection and maintenance

  • Flat back design for easy mounting close to walls
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LC050
LC075
LC100
LC125
LC150
LC200
LC250
LC300
LC350
LC400
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
33.4
ABCVolume
33.5
ABCVolume
69.5
ABCVolume
159
ABCVolume
188
ABCVolume
307
ABCVolume
309
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type C

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): Threaded
Feature(s): Type C

Conduit bodies are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction.

  • Flat back design for easy mounting close to walls
  • Assembled with removable cover and gasket
  • Stamped aluminum cover
  • Rubber gasket
Model Number
LC050AN
LC075AN
LC100AN
LC125AN
LC150AN
LC200AN
LC250AN
LC300AN
LC350AN
LC400AN
ABCVolume
4.81.31.64.35
ABCVolume
5.51.51.97.3
ABCVolume
6.221.752.0712.2
ABCVolume
8.272.482.8433.4
ABCVolume
8.272.482.8433.5
ABCVolume
10.243.133.5969.5
ABCVolume
159
ABCVolume
188
ABCVolume
307
ABCVolume
309
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Mogul Conduit Body – Type LB

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): MogulType LB

Mogul conduit bodies are used to gain greater access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction.

  • Meets NEC 6x requirement
  • Listed for use in wet locations
  • Assembled with removable cover and fiber gasket
Model Number
LBMO125CG
LBMO150CG
LBMO200CG
ABCVolume
9.672.524.2940
ABCVolume
14.573.196.32128
ABCVolume
14.573.196.32128
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Set Screw Conduit Body – Type LB

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): Conduit Body
Connection Type(s): 90 DegreeSet Screw
Feature(s): Type LB

Used with EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Set screw hubs to accommodate EMT
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LBSS050
LBSS075
LBSS100
LBSS125
LBSS150
LBSS200
LBSS250
LBSS300
LBSS350
LBSS400
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
32.3
ABCVolume
33.8
ABCVolume
71.2
ABCVolume
153
ABCVolume
183.5
ABCVolume
304.9
ABCVolume
308
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Set Screw Conduit Body – Type LB

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): Conduit Body
Connection Type(s): 90 DegreeSet Screw
Feature(s): Type LB

Conduit bodies are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction. Pre-assembled with a cover and gasket. For dry location applications.

  • Type LB
  • Flat back design for easy mounting close to walls
  • Assembled with removable cover and rubber gasket
Model Number
LBSS050AN
LBSS075AN
LBSS100AN
LBSS125AN
LBSS150AN
LBSS200AN
LBSS250AN
LBSS300AN
LBSS350AN
LBSS400AN
ABCVolume
4.341.312.44.35
ABCVolume
5.091.542.67.3
ABCVolume
12.2
ABCVolume
32.3
ABCVolume
33.8
ABCVolume
71.2
ABCVolume
153
ABCVolume
183.5
ABCVolume
304.9
ABCVolume
308
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Combination Conduit Body – Type LB

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMTRigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeCombinationSet ScrewThreaded
Feature(s): Type LB

Used with threaded rigid conduit, IMC or EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LBC050
LBC075
LBC0100
LBC0125
LBC150
LBC200
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
32.3
ABCVolume
33.8
ABCVolume
71.2
UL: E121488
CSA: LR57925

Standards: UL 514A & 514B, CSA C22.2 No. 18.1-13 & C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Combination Conduit Body – Type LB

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMTRigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeCombinationSet ScrewThreaded
Feature(s): Type LB

Used with threaded rigid conduit, IMC or EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Flat back design for easy mounting close to walls
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LBC050AN
LBC075AN
LBC100AN
LBC125AN
LBC150AN
LBC200AN
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
32.3
ABCVolume
33.8
ABCVolume
71.2
UL: E121488
CSA: LR57925

Standards: UL 514A & 514B, CSA C22.2 No. 18.1-13 & C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type LB

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): Type LB

Used with threaded rigid conduit or IMC for providing access to the interior of a conduit system for pulling, splicing, inspection and maintenance

  • Flat back design for easy mounting close to walls
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LB050CG
LB075CG
LB100CG
LB125CG
LB150CG
LB200CG
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
32.3
ABCVolume
33.8
ABCVolume
71.2
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Grounding Lug

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Grounding
Type(s): Lug

Used to bond wires and surfaces for grounding applications

  • Lay-in option allows quick and easy installation even after conductors are run
  • Listed for use with solid and stranded, copper and aluminum conductors
Model Number
LB2/0
ABCVolume
cULus: E257216

Standards: UL 467, UL 486A-486B, CSA C22.2 No. 41-13, CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type LB

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): Type LB

Used with threaded rigid conduit or IMC for providing access to the interior of a conduit system for pulling, splicing, inspection and maintenance

  • Flat back design for easy mounting close to walls
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
LB050
LB075
LB100
LB125
LB150
LB200
LB250
LB300
LB350
LB400
ABCVolume
4.35
ABCVolume
7.3
ABCVolume
12.2
ABCVolume
32.3
ABCVolume
33.8
ABCVolume
71.2
ABCVolume
153
ABCVolume
183.5
ABCVolume
304.9
ABCVolume
308
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type LB

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): Type LB

Conduit bodies are used to gain access to the interior of a raceway for wire pulling, inspection and maintenance where the raceway changes direction.

  • Flat back design for easy mounting close to walls
  • Assembled with removable cover and gasket
  • Stamped aluminum cover
  • Rubber gasket
Model Number
LB050AN
LB075AN
LB100AN
LB125AN
LB150AN
LB200AN
LB250AN
LB300AN
LB350AN
LB400AN
ABCVolume
4.31.32.44.35
ABCVolume
51.52.67.3
ABCVolume
5.81.82.912.2
ABCVolume
7.82.53.732.3
ABCVolume
7.82.53.933.8
ABCVolume
9.83.24.771.2
ABCVolume
12.834.445.35153
ABCVolume
12.834.445.96183.5
ABCVolume
304.9
ABCVolume
308
UL: E121488
CSA: LR57925

Standards: UL 514A & UL 514B, CSA C22.2 No. 18.1-13 & CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Grounding Lug

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Grounding
Type(s): Lug

Used to bond wires and surfaces for grounding applications

  • Lay-in option allows quick and easy installation even after conductors are run
  • Listed for use with solid and stranded, copper and aluminum conductors
Model Number
LB4
ABCVolume
cULus: E257216

Standards: UL 467, UL 486A-486B, CSA C22.2 No. 41-13, CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Grounding Lug

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Grounding
Type(s): Lug

Used to bond wires and surfaces for grounding applications

  • Lay-in option allows quick and easy installation even after conductors are run
  • Listed for use with solid and stranded, copper and aluminum conductors
Model Number
LB2
ABCVolume
cULus: E257216

Standards: UL 467, UL 486A-486B, CSA C22.2 No. 41-13, CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Grounding Lug

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Grounding
Type(s): Lug

Used to bond wires and surfaces for grounding applications

  • Lay-in option allows quick and easy installation even after conductors are run
  • Listed for use with solid and stranded, copper and aluminum conductors
Model Number
LB1/0
ABCVolume
cULus: E257216

Standards: UL 467, UL 486A-486B, CSA C22.2 No. 41-13, CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Grounding Lug

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Grounding
Type(s): Lug

Used to bond wires and surfaces for grounding applications

  • Lay-in option allows quick and easy installation even after conductors are run
  • Listed for use with solid and stranded, copper and aluminum conductors
  • Listed for Direct Burial and is ideal for swimming pool and solar grounding applications
Model Number
LC1/0CU
ABCVolume
cULus: E257216

Standards: UL 467, UL 486A-486B, CSA C22.2 No. 41-13, CSA C22.2 No. 65-13
< Products

Solderless Terminal Lug

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Grounding
Type(s): Lug

Solderless terminal lugs are used to connect wires to a metal enclosure.

  • One hole, single collar
Model Number
LC3/0CU
ABCVolume
cULus: E257216

Standards: UL 467, UL 486A-486B, CSA C22.2 No. 41-13, CSA C22.2 No. 65-13
< Products

Grounding Lug

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Grounding
Type(s): Lug

Used to bond wires and surfaces for grounding applications

  • Lay-in option allows quick and easy installation even after conductors are run
  • Listed for use with solid and stranded, copper and aluminum conductors
  • Listed for Direct Burial and is ideal for swimming pool and solar grounding applications
Model Number
LC250CU
ABCVolume
cULus: E257216

Standards: UL 467, UL 486A-486B, CSA C22.2 No. 41-13, CSA C22.2 No. 65-13
< Products

Grounding Lug

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Grounding
Type(s): Lug

Used to bond wires and surfaces for grounding applications

  • Lay-in option allows quick and easy installation even after conductors are run
  • Listed for use with solid and stranded, copper and aluminum conductors
  • Listed for Direct Burial and is ideal for swimming pool and solar grounding applications
Model Number
LA4C
ABCVolume
cULus: E257216

Standards: UL 467, UL 486A-486B, CSA C22.2 No. 41-13, CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Grounding Lug

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Grounding
Type(s): Lug

Used to bond wires and surfaces for grounding applications

  • Lay-in option allows quick and easy installation even after conductors are run
  • Listed for use with solid and stranded, copper and aluminum conductors
  • Listed for Direct Burial and is ideal for swimming pool and solar grounding applications
  • Tin plated
Model Number
LA4CP
ABCVolume
cULus: E257216

Standards: UL 467, UL 486A-486B, CSA C22.2 No. 41-13, CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Grounding Lug

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Grounding
Type(s): Lug

Used to bond wires and surfaces for grounding applications

  • Lay-in option allows quick and easy installation even after conductors are run
  • Listed for use with solid and stranded, copper and aluminum conductors
  • Listed for Direct Burial and is ideal for swimming pool and solar grounding applications
Model Number
LC4CU
ABCVolume
cULus: E257216

Standards: UL 467, UL 486A-486B, CSA C22.2 No. 41-13, CSA C22.2 No. 65-13
< Products

Grounding Lug

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Grounding
Type(s): Lug

Used to bond wires and surfaces for grounding applications

  • Lay-in option allows quick and easy installation even after conductors are run
  • Listed for use with solid and stranded, copper and aluminum conductors
Model Number
LA1/0
ABCVolume
cULus: E257216

Standards: UL 467, UL 486A-486B, CSA C22.2 No. 41-13, CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Grounding Lug

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Grounding
Type(s): Lug

Used to bond wires and surfaces for grounding applications

  • Lay-in option allows quick and easy installation even after conductors are run
  • Listed for use with solid and stranded, copper and aluminum conductors
Model Number
LA3/0
ABCVolume
cULus: E257216

Standards: UL 467, UL 486A-486B, CSA C22.2 No. 41-13, CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Grounding Lug

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Grounding
Type(s): Lug

Used to bond wires and surfaces for grounding applications

  • Lay-in option allows quick and easy installation even after conductors are run
  • Listed for use with solid and stranded, copper and aluminum conductors
Model Number
LA250
ABCVolume
cULus: E257216

Standards: UL 467, UL 486A-486B, CSA C22.2 No. 41-13, CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Knockout Seal

Material: Zinc-Plated Steel
Category: Fittings
Sub Category: Accessories
Type(s): Knockout Seal

Knockout seals are used to close exposed holes in an outlet box or metal enclosure.

Model Number
KOS050
KOS075
KOS100
KOS125
KOS150
KOS200
ABCVolume
0.911.070.3
ABCVolume
1.151.220.31
ABCVolume
1.411.480.34
ABCVolume
1.771.890.35
ABCVolume
2.022.190.31
ABCVolume
2.512.650.33
< Products

Grounding Lug

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Grounding
Type(s): Lug

Used to bond wires and surfaces for grounding applications

  • Lay-in option allows quick and easy installation even after conductors are run
  • Listed for use with solid and stranded, copper and aluminum conductors
Model Number
LA4
ABCVolume
cULus: E257216

Standards: UL 467, UL 486A-486B, CSA C22.2 No. 41-13, CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Grounding Lug

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Grounding
Type(s): Lug

Used to bond wires and surfaces for grounding applications

  • Lay-in option allows quick and easy installation even after conductors are run
  • Listed for use with solid and stranded, copper and aluminum conductors
Model Number
LA2
ABCVolume
cULus: E257216

Standards: UL 467, UL 486A-486B, CSA C22.2 No. 41-13, CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Jumper Clamp

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Jumper Clamp

Used to provide an easy jumper connection with a wide range of conductors

  • Parallel groove design doesn’t require removal of bolt for installation
  • Cast from high strength, highly conductive copper alloy
  • Fully tin plated
Model Number
K2
ABCVolume
UL: E88878

65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Jumper Clamp

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Jumper Clamp

Used to provide an easy jumper connection with a wide range of conductors

  • Parallel groove design doesn’t require removal of bolt for installation
  • Cast from high strength, highly conductive copper alloy
  • Not plated
Model Number
K3
ABCVolume
UL: E88878

65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Jumper Clamp

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Jumper Clamp

Used to provide an easy jumper connection with a wide range of conductors

  • Parallel groove design doesn’t require removal of bolt for installation
  • Cast from high strength, highly conductive copper alloy
  • Fully tin plated
  • Available with Stainless Steel hardware
Model Number
KUL
ABCVolume
UL: E88878

65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Intersystem Bonding Bridge

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Grounding
Type(s): Intersystem Bonding Bridge

Used in residential and commercial applications to ground up to 4 systems to a single location

  • Meets 2011 NEC Clause 250.94 for Intersystem Bonding Termination
  • Lay-in style connection for up to 4 auxiliary ground wires – 1 more than NEC requirement
  • Plastic cover provides an aesthetically pleasing installation and provides protection
  • Approved for use with solid or stranded copper conductors
  • Assembled with stainless steel screws and plastic cover
Model Number
IBBZ03Z
ABCVolume
cULus: E88878

Standards: UL 467, UL 486A-486B, CSA C22.2 No. 41-13, CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

360° Swivel Hub

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Hub
Feature(s): Swivel Hub

Used to connect bare or armored copper wire to steel or copper water pipe

  • Integral clamp swivels 360° for easy alignment
  • Cast from high strength, highly conductive copper alloy
  • Zinc plated steel hardware
Model Number
JA
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Jumper Clamp

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Jumper Clamp

Used to provide an easy jumper connection with a wide range of conductors

  • Parallel groove design doesn’t require removal of bolt for installation
  • Cast from high strength, highly conductive copper alloy
  • One groove plating removed
Model Number
K1
ABCVolume
UL: E88878

65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Intersystem Bonding Bridge

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Intersystem Bonding Bridge

Used in residential and commercial applications to ground up to 4 systems to a single location

  • Meets 2011 NEC Clause 250.94 for Intersystem Bonding Termination
  • Lay-in style connection for up to 4 auxiliary ground wires – 1 more than NEC requirement
  • Plastic cover provides an aesthetically pleasing installation and provides protection
  • Approved for use with solid or stranded copper conductors
  • Assembled with stainless steel screws and plastic cover
Model Number
IBBCU03
ABCVolume
cULus: E88878

Standards: UL 467, UL 486A-486B, CSA C22.2 No. 41-13, CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Intersystem Bonding Bridge

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Grounding
Type(s): Intersystem Bonding Bridge

Used in residential and commercial applications to ground up to 4 systems to a single location

  • Meets 2011 NEC Clause 250.94 for Intersystem Bonding Termination
  • Lay-in style connection for up to 4 auxiliary ground wires – 1 more than NEC requirement
  • Plastic cover provides an aesthetically pleasing installation and provides protection
  • Approved for use with solid or stranded copper conductors
  • Assembled with stainless steel screws and plastic cover
Model Number
IBB03
ABCVolume
cULus: E88878

Standards: UL 467, UL 486A-486B, CSA C22.2 No. 41-13, CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Intersystem Bonding Bridge

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Grounding
Type(s): Intersystem Bonding Bridge

IBBs are used in residential and commercial applications to ground up to 4 systems to a single location.

  • Meets NEC 2011 article 250.94
  • Lay-in lug style
  • Connection for up to 4 auxiliary
    ground wires (1 more than NEC requirement)
  • Approved for solid or stranded copper conductors
  • Stainless steel screws
  • Non-metallic cover (not UL listed)
Model Number
IBBZ03
ABCVolume
4.331.581.39
cULus: E88878

Standards: UL 467, UL 486A-486B, CSA C22.2 No. 41-13, CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Hub

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Hub

Used with grounding pipe clamps to connect rigid conduit to water pipe for grounding

  • Used with a Copper strap (not included) that allows flexibility during and after installation and helps protect conduit from vibration
  • Cast from high strength, highly conductive copper alloy
Model Number
H2
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Hub

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Hub

Used with grounding pipe clamps to connect rigid conduit to water pipe for grounding

  • Used with a Copper strap (not included) that allows flexibility during and after installation and helps protect conduit from vibration
  • Cast from high strength, highly conductive copper alloy
Model Number
H3
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Ground Rod Clamp

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Clamp
Connection Type(s): Ground Rod

Used to connect bare copper wire to copper ground rod or rebar

  • Cast from high strength, highly conductive copper alloy
  • All listed models approved for Direct Burial
    in earth and concrete
  • With bronze hex bolt
Model Number
HDC34S
ABCVolume
cULus: E88878

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing – Feed-Through Lug

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): Feed-thruGrounding
Feature(s): Insulated

Insulated metallic grounding bushings are used on the end of Rigid conduit, IMC and other threaded connectors to provide a smooth well rounded bearing surface to protect wires or cables as well as provide a means to connect a grounding conductor.

  • Feed-through lug style
  • Includes nylon insulator rated 150°C
  • Aluminum Lug
Model Number
GBILB050
GBILB075
GBILB100
GBILB125
GBILB150
GBILB200
GBILB250
GBILB300
GBILB350
GBILB400
ABCVolume
1.040.50.54
ABCVolume
1.280.50.74
ABCVolume
1.520.590.96
ABCVolume
1.870.611.27
ABCVolume
2.160.611.49
ABCVolume
2.670.611.93
ABCVolume
3.230.832.33
ABCVolume
3.850.832.93
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 467 & 486A-486B, CSA C22.2 No. 41-13 & CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Conduit Bushing without Lug

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): Insulating
Feature(s): Insulated

Used to terminate threaded rigid conduit or IMC to an enclosure

  • Bushing throat provides a smooth surface to prevent damage to wire during pulling
  • With 150°C rated insulator
Model Number
GBI050T
GBI075T
GBI100T
GBI125T
GBI150T
GBI200T
GBI250T
GBI300T
GBI350T
GBI400T
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E155411

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Hub

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Hub

Used with grounding pipe clamps to connect rigid conduit to water pipe for grounding

  • Used with a Copper strap (not included) that allows flexibility during and after installation and helps protect conduit from vibration
  • Cast from high strength, highly conductive copper alloy
Model Number
H1
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Lay-in-Lug

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate threaded rigid conduit, or IMC to an enclosure

  • Provided with lay-in style aluminum lug for easy attachment of grounding wire
  • With 150°C rated insulator
  • With larger lug for greater range of cables
Model Number
GBILA200S
GBILA250S
GBILA300S
GBILA350S
GBILA400S
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 467 & 486A-486B, CSA C22.2 No. 41-13 & CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Lay-in-Lug

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate threaded rigid conduit, or IMC to an enclosure

  • Provided with lay-in style aluminum lug for easy attachment of grounding wire
  • With 150°C rated insulator
  • With 3 tapped holes
  • With larger lug for greater range of cables
Model Number
GBILA350ST
GBILA400ST
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 467 & 486A-486B, CSA C22.2 No. 41-13 & CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Lay-in-Lug

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate threaded rigid conduit, or IMC to an enclosure

  • Provided with lay-in style aluminum lug for easy attachment of grounding wire
  • With 150°C rated insulator
  • With 3 tapped holes
Model Number
GBILA050T
GBILA075T
GBILA100T
GBILA125T
GBILA150T
GBILA200T
GBILA250T
GBILA300T
GBILA350T
GBILA400T
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 467 & 486A-486B, CSA C22.2 No. 41-13 & CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing – Lay-In Lug

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Insulated metallic grounding bushings are used on the end of Rigid conduit, IMC and other threaded connectors to provide a smooth well rounded bearing surface to protect wires or cables as well as provide a means to connect a grounding conductor.

  • Lay-in lug style
  • Includes nylon insulator rated 150°C
  • Aluminum Lug
Model Number
GBILA050
GBILA075
GBILA100
GBILA125
GBILA150
GBILA200
ABCVolume
1.040.50.54
ABCVolume
1.280.50.74
ABCVolume
1.540.590.96
ABCVolume
1.870.611.27
ABCVolume
2.160.611.49
ABCVolume
2.670.611.93
cULus: E88878

Standards: UL 467 & 486A-486B, CSA C22.2 No. 41-13 & CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing with Lay-in-Lug

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Used to terminate threaded rigid conduit, or IMC to an enclosure

  • Provided with lay-in style aluminum lug for easy attachment of grounding wire
  • With 150°C rated insulator
Model Number
GBILA250
GBILA300
GBILA350
GBILA400
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 467 & 486A-486B, CSA C22.2 No. 41-13 & CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Grounding Bushing – Lay-In Lug

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): GroundingLay-In-Lug
Feature(s): Insulated

Insulated metallic grounding bushings are used on the end of Rigid conduit, IMC and other threaded connectors to provide a smooth well rounded bearing surface to protect wires or cables as well as provide a means to connect a grounding conductor.

  • Lay-in lug style
  • Includes nylon insulator rated 150°C
  • Aluminum Lug
  • With larger lug for greater range of cables
Model Number
GBILA125S
GBILA150S
ABCVolume
ABCVolume
cULus: E88878

Standards: UL 467 & 486A-486B, CSA C22.2 No. 41-13 & CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body Gasket

Material: Fiber
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): Gasket

Used with aluminum conduit bodies to seal enclosure with covers

Model Number
FG050
FG075
FG100
FG150
FG200
FG300
FG400
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
65!
WARNING:
Risk of reproductive harm from exposure to Bisphenol A (BPA).
See www.P65Warnings.ca.gov
< Products

Conduit Bushing

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Bushing

Used to terminate rigid conduit or IMC to an enclosure

Model Number
GB050
GB075
GB100
GB125
GB150
GB200
GB250
GB300
GB350
GB400
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA 22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Conduit Bushing

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Bushing
Connection Type(s): Insulating
Feature(s): Insulated

Used to terminate rigid conduit or IMC to an enclosure

  • Bushing throat provides a smooth surface to prevent damage to wire during pulling
  • With 150°C rated insulator
Model Number
GBI050
GBI075
GBI100
GBI125
GBI150
GBI200
GBI250
GBI300
GBI350
GBI400
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA 22.2 No. 18
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Combination Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): Combination

Combination connectors are used to terminate AC, MC or FMC to a knockout in a dry location box or enclosure.

  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
FBMC037
ABCVolume
0.741.160.36
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Set Screw Flex Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): Set Screw

Set screw flex connectors are used to terminate FMC/RWFMC to a knockout in a dry location box or enclosure.

  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
FCA050
FCA075
ABCVolume
0.961.480.4
ABCVolume
1.151.550.49
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Insulated Set Screw Flex Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): Set Screw
Feature(s): Insulated

Set screw flex connectors are used to terminate FMC/RWFMC to a knockout in a dry location box or enclosure.

  • 90° C rated throat insulator
  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
FCA050I
FCA075I
ABCVolume
0.961.550.4
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

90˚ EMT Elbow

Material: Galvanized Steel
Category: Fittings
Sub Category: EMT
Type(s): Elbow
Connection Type(s): 90 Degree

90° elbows are used to connect steel EMT conduit together to allow for 90° bends.

Model Number
EEN050
EEN075
EEN100
EEN125
EEN150
EEN200
ABCVolume
0.714.026.25
ABCVolume
0.924.497.06
ABCVolume
1.165.759.25
ABCVolume
1.517.2410.5
ABCVolume
1.748.2712.63
ABCVolume
2.29.4914.25
cULus: E364687

Standards: UL 797, CSA C22.2 No. 83.1-07
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

One-Hole Strap

Material: Zinc-Plated Steel
Category: Fittings
Sub Category: EMT
Type(s): Strap
Connection Type(s): One-Hole

One-hole straps are used to provide support for steel EMT conduit as required by the National Electric Code (NEC).

  • Snap-on type
Model Number
ES0501
ES0751
ES1001
ES1251
ES1501
ES2001
ABCVolume
1.660.550.74
ABCVolume
1.90.630.91
ABCVolume
2.130.761.13
ABCVolume
2.830.891.46
ABCVolume
3.1211.82
ABCVolume
3.821.062.22
cULus: E229278

Standards: UL 2239, CSA C22.2 No. 18.4-15
< Products

Two-Hole Strap

Material: Zinc-Plated Steel
Category: Fittings
Sub Category: EMT
Type(s): Strap
Connection Type(s): Two-Hole

Two-hole straps are used to provide support for steel EMT conduit where higher load bearing supports are needed as required by the National Electric Code (NEC).

  • Snap-on type
Model Number
ES0502
ES0752
ES1002
ES1252
ES1502
ES2002
ABCVolume
2.130.550.75
ABCVolume
2.620.630.95
ABCVolume
2.80.691.11
ABCVolume
3.250.751.43
ABCVolume
4.090.871.67
ABCVolume
4.7612.21
cULus: E229278

Standards: UL 2239, CSA C22.2 No. 18.4-15
< Products

Insulators for Service Entrance Heads

Material: Non-Metallic
Category: Fittings
Sub Category: NMSE
Type(s): Phenolic Insulators

Used with clamp-on, threaded, set screw and mast type service entrance heads

Model Number
ECI050
ECI075
ECI100
ECI125
ECI150
ECI200
ECI250
ECI3006
ECI3007
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
< Products

Snap Lock® Compression Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): Connector
Connection Type(s): Compression
Feature(s): Concrete-TightRain-TightSnap Lock®

Snap Lock® compression type connectors are used to secure and terminate steel EMT conduit to a knockout in a metal box or enclosure. The patent-pending Snap Lock® design provides a faster installation allowing the EMT conduit to snap into the fitting without the use of tools. For wet or dry location applications.

  • Conduit snaps into connector
  • Concrete-tight
  • Rain-tight
Model Number
ECON050
ECON075
ABCVolume
1.151.260.39
ABCVolume
1.181.50.39
cULus: E210498

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Snap Lock® Compression Coupling

Material: Zinc Die-Cast
Category: Fittings
Sub Category: EMT
Type(s): Coupling
Connection Type(s): Compression
Feature(s): Concrete-TightRain-TightSnap Lock®

Snap Lock® compression type couplings are used to join lengths of steel EMT conduit without the use of tools. The patent pending Snap Lock® design provides a faster installation. For wet location applications.

  • Conduit snaps into coupling
  • Concrete-tight
  • Rain-tight
Model Number
ECOP050
ECOP075
ABCVolume
1.351.260.81
ABCVolume
1.431.51.03
cULus: E210498

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Double Snap Lock® Duplex Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): Duplex
Feature(s): Double Snap Lock®Snap Lock®

Double Snap Lock® duplex connectors are used to terminate two runs of AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure. The patented Double Snap Lock® design provides a faster installation.

  • No tools required
  • Robust insulator will not fall out
  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
DUP1DSI
ABCVolume
2.11.490.4
cULus: E155411

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Snap Lock® Duplex Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): Duplex
Feature(s): Snap Lock®

Snap Lock® duplex connectors are used to terminate two runs of AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure.

  • Faster installation with no locknut required
  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
DUP1S
ABCVolume
1.641.450.41
cULus: E155411

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Double Snap Lock® Duplex Connector – Steel

Material: Zinc-Plated Steel
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): Duplex
Feature(s): Double Snap Lock®Snap Lock®

Double Snap Lock® duplex connectors are used to terminate two runs of AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure. The patented Double Snap Lock® design provides a faster installation.

  • No tools required
  • Robust insulator will not fall out
  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
DUPS1DSI
ABCVolume
cULus: E155411

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of reproductive harm from exposure to Bisphenol A (BPA).
See www.P65Warnings.ca.gov
< Products

Strain Relief Box Connector

Material: Zinc Die-Cast
Category: FittingsStrain Relief
Sub Category: Strain Relief
Type(s): Connector
Connection Type(s): Cord GripStraight
Feature(s): with Mesh

Used to seal, provide strain relief and terminate portable or flexible cords to metal enclosure or box

  • Suitable for use with S, SO, ST, STO, SJ, SJT, SJTO, SJOOW, SOOW, STOOW, SJTOOW and SVO cords
  • Zinc die-cast fittings with galvanized steel single weave mesh
  • Rubber grommet provides water-tight seal
  • Insulated
Model Number
DC05022I
DC05030I
DC05040I
DC07552I
DC10070I
DC12594I
DC150120I
DC200140I
ABCVolume
ABCVolume
7.871.781.12
ABCVolume
9.251.931.36
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E121487
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Duplex Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): Duplex

Duplex connectors are used to terminate two runs of AC, MC or FMC/RWFMC to a knockout in a dry location box or enclosure.

  • Clamp type
  • Single screw
  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
DUP1
ABCVolume
1.61.490.42
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Duplex Connector

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Flex
Type(s): Connector
Connection Type(s): Duplex

Used to terminate flexible metal conduit, armored or metal clad cables to an enclosure

  • With two zinc plated steel screws
  • Die-cast from high strength zinc alloy
  • Refer to Connector Listing PDF under RESOURCES tab below for specific cable and conduit ranges
Model Number
DUP2
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Ground Clamp

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Grounding
Type(s): Clamp
Connection Type(s): Bare Wire

Ground clamps are used to connect bare or insulated copper wire to copper or galvanized steel water pipe.

Model Number
CZ11
ABCVolume
2.241.340.63
UL: E88878
CSA: LR57925

Standards: UL 467, UL 486A-486B, CSA C22.2 No. 41-13, CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Ground Clamp for Bare Wire

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Grounding
Type(s): Clamp
Connection Type(s): Bare Wire

Used to connect copper or aluminum ground conductor to galvanized water pipe, copper water tubing, or ground rod

  • Cast from high strength zinc alloy
  • Zinc plated
Model Number
CZ11P
ABCVolume
CSA: LR57925

Standards: UL 467, UL 486A-486B, CSA C22.2 No. 41-13, CSA C22.2 No. 65-13
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Ground Clamp for Armored Wire

Material: Zinc-Plated Steel
Category: Fittings
Sub Category: Grounding
Type(s): Clamp
Connection Type(s): Armored Wire

Used to connect bare or armored copper wire to steel water pipe

  • Integral clamp securely holds armor
  • Zinc plated steel hardware
  • Cast from high strength zinc alloy
Model Number
CZ6
CZ6P
ABCVolume
ABCVolume
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

EMT-to-Flex Coupling

Material: Zinc Die-Cast
Category: Fittings
Sub Category: EMTFlex
Type(s): Coupling
Connection Type(s): CompressionScrew-In
Feature(s): Combination

Combination couplings are used to provide a transition from steel EMT conduit to Flexible Metal Conduit. For dry location applications.

  • Compression type
Model Number
CSICP050
CSICP075
CSICP100
ABCVolume
1.40.980.15
ABCVolume
1.521.230.21
ABCVolume
1.991.520.31
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Ground Clamp for Direct Burial

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Clamp
Connection Type(s): Direct Burial

Ground clamps are used to connect bare or insulated copper wire to copper or galvanized steel water pipe.

  • Suitable for direct burial in ground and concrete
  • Stainless steel screws
Model Number
C11SS
ABCVolume
2.251.380.63
cULus: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Direct Burial Bronze Ground Clamp for Bare Wire

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Clamp
Connection Type(s): Direct Burial

Used to connect bare copper wire to galvanized steel water pipe or copper tubing

  • Cast from high strength, highly conductive copper alloy
  • Stainless steel hardware
Model Number
C22SS
ABCVolume
cULus: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

UF Connector

Material: Non-Metallic
Category: FittingsStrain Relief
Sub Category: Strain Relief
Type(s): Connector
Connection Type(s): StraightUnderground Feeder Cable

Used to seal, provide strain relief and terminate portable or flexible cords to metal enclosure or box

  • Suitable for use with UF cords
  • Plastic fittings
  • Rubber grommet provides water-tight seal
Model Number
CNS501UF
CNS502UF
CNS751UF
CNS752UF
ABCVolume
ABCVolume
cCSAus: 174008

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl)phthalate.
See www.P65Warnings.ca.gov
< Products

Clamp-On Service Entrance Head

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: NMSE
Type(s): Service Entrance Head
Connection Type(s): Clamp-On

Service entrance heads are used as a connecting point in an overhead service entrance and can be mounted on threaded or unthreaded Rigid, IMC or EMT conduit.

  • Clamp-on type
  • Phenolic insulator with multiple holes
  • Listed for use in wet locations
Model Number
CO050
CO075
CO100
CO125
CO150
CO200
CO250
CO300
ABCVolume
2.252.221.93
ABCVolume
2.482.512.2
ABCVolume
2.752.852.55
ABCVolume
3.122.92.98
ABCVolume
3.753.683.18
ABCVolume
4.345.284.61
ABCVolume
5.5910.596.14
ABCVolume
6.3810.716.14
UL: E121487
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Service Entrance Heads – Clamp-on Type

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: NMSE
Type(s): Service Entrance Head
Connection Type(s): Clamp-On

Clamp-on type head used with rigid conduit, IMC or EMT for pulling service drop conductors

  • Assembled with electrical grade insulator with multiple holes
  • UL listed and CSA certified for wet location use
  • Die-cast from high strength, corrosion and weather resistant aluminum alloy
Model Number
CO300L
CO350
CO400
ABCVolume
ABCVolume
ABCVolume
UL: E121487
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Cord Grip Non-metallic Connector (without mesh)

Material: Non-Metallic
Category: FittingsStrain Relief
Sub Category: Strain Relief
Type(s): Connector
Connection Type(s): Cord GripStraight

Used to seal, provide strain relief and terminate portable or flexible cords to metal enclosure or box

  • Suitable for use with S, SO, ST, STO, SJ, SJT, SJTO, SJOOW, SOOW, STOOW, SJTOOW and SVO cords
  • Plastic fittings
  • Rubber grommet provides water-tight seal
Model Number
CNS509B
CNS5011B
CNS5012B
CNS5013B
CNS5015B
CNS757B
CNS7510B
CNS7512B
CNS7514B
CNS7516B
CNS7518B
CNS7519B
CNS10019B
CNS10020B
CNS10021B
CNS10022B
CNS10023B
ABCVolume
ABCVolume
ABCVolume
cCSAus: 174008

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl)phthalate.
See www.P65Warnings.ca.gov
< Products

Cord Grip Non-metallic Connector

Material: Non-Metallic
Category: FittingsStrain Relief
Sub Category: Strain Relief
Type(s): Connector
Connection Type(s): Cord GripStraight
Feature(s): with Mesh

Used to seal, provide strain relief and terminate portable or flexible cords to metal enclosure or box

  • Suitable for use with S, SO, ST, STO, SJ, SJT, SJTO, SJOOW, SOOW, STOOW, SJTOOW and SVO cords
  • Plastic fittings with stainless steel single/double weave mesh
  • Rubber grommet provides water-tight seal
Model Number
CNS507M
CNS509M
CNS5011M
CNS5012M
CNS5013M
CNS5015M
CNS5017M
CNS757M
CNS7510M
CNS7512M
CNS7514M
CNS7516M
CNS7518M
CNS7519M
CNS7520M
CNS10014M
CNS10016M
CNS10018M
CNS10019M
CNS10020M
CNS10021M
CNS10022M
CNS10023M
ABCVolume
ABCVolume
ABCVolume
cCSAus: 174008

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl)phthalate.
See www.P65Warnings.ca.gov
< Products

Cord Grip Non-metallic Connector

Material: Non-Metallic
Category: FittingsStrain Relief
Sub Category: Strain Relief
Type(s): Connector
Connection Type(s): Cord GripStraight
Feature(s): with Mesh

Used to seal, provide strain relief and terminate portable or flexible cords to metal enclosure or box

  • Suitable for use with S, SO, ST, STO, SJ, SJT, SJTO, SJOOW, SOOW, STOOW, SJTOOW and SVO cords
  • Plastic fittings with plastic single/double weave mesh
  • Rubber grommet provides water-tight seal
Model Number
CNS507N
CNS509N
CNS5011N
CNS5012N
CNS5013N
CNS757N
CNS7510N
CNS7512N
CNS7514N
CNS7516N
CNS7518N
CNS7519N
CNS10014N
CNS10016N
CNS10018N
CNS10019N
CNS10020N
CNS10021N
CNS10022N
CNS10023N
ABCVolume
ABCVolume
8.272.31.3
ABCVolume
ABCVolume
8.52.591.55
ABCVolume
cCSAus: 174008

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl)phthalate.
See www.P65Warnings.ca.gov
< Products

90° Cord Grip Non-metallic Connector

Material: Non-Metallic
Category: FittingsStrain Relief
Sub Category: Strain Relief
Type(s): Connector
Connection Type(s): 90 DegreeCord Grip
Feature(s): with Mesh

Used to seal, provide strain relief and terminate portable or flexible cords to metal enclosure or box

  • Suitable for use with S, SO, ST, STO, SJ, SJT, SJTO, SJOOW, SOOW, STOOW, SJTOOW and SVO cords
  • 90° Angular
  • Plastic fittings with plastic single/double weave mesh
  • Rubber grommet provides water-tight seal
Model Number
CNA507N
CNA509N
CNA5011N
CNA5012N
CNA5013N
CNA7510N
CNA7512N
CNA7514N
CNA7516N
CNA7518N
CNA7519N
CNA10014N
CNA10016N
CNA10019N
CNA10020N
CNA10021N
CNA10023N
ABCVolume
ABCVolume
ABCVolume
cCSAus: 174008

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl)phthalate.
See www.P65Warnings.ca.gov
< Products

Insulated Conduit Nipple

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Nipple
Feature(s): Insulated

Used with locknut to serve as a short raceway between enclosures

  • With 90° C rated insulated throat
Model Number
CN050I
CN075I
CN100I
CN125I
CN150I
CN200I
CN250I
CN300I
CN350I
CN400I
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Cord Grip Non-metallic Connector (without mesh)

Material: Non-Metallic
Category: FittingsStrain Relief
Sub Category: Strain Relief
Type(s): Connector
Connection Type(s): Cord GripStraight

Used to seal, provide strain relief and terminate portable or flexible cords to metal enclosure or box

  • Suitable for use with S, SO, ST, STO, SJ, SJT,
    SJTO, SJOOW, SOOW, STOOW, SJTOOW and SVO cords
  • Plastic fittings
  • Rubber grommet provides water-tight seal
Model Number
CNS254
CNS256
CNS258
CNS375
CNS377
CNS379
CNS3711
CNS3712
CNS503
CNS505
CNS507
CNS509
CNS5011
CNS5012
CNS5013
CNS5015
CNS5017
CNS757
CNS7510
CNS7512
CNS7514
CNS7516
CNS7518
CNS7519
CNS7520
CNS10014
CNS10016
CNS10018
CNS10019
CNS10020
CNS10021
CNS10022
CNS10023
CNS10024
CNS12521
CNS12523
CNS12524
CNS12525
CNS12526
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cCSAus: 174008

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl)phthalate.
See www.P65Warnings.ca.gov
< Products

Conduit Nipple

Material: Zinc Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Nipple

Conduit nipples are used in conjunction with locknuts to provide a short raceway between two outlet boxes or metal enclosures.

Model Number
CN050
CN075
CN100
CN125
CN150
CN200
CN250
CN300
CN350
CN400
ABCVolume
0.930.590.44
ABCVolume
1.190.710.5
ABCVolume
1.390.840.62
ABCVolume
1.750.880.63
ABCVolume
2.130.910.63
ABCVolume
2.551.020.72
ABCVolume
3.221.441.04
ABCVolume
ABCVolume
ABCVolume
UL: E155411
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

90° Cord Grip Non-metallic Connector (without mesh)

Material: Non-Metallic
Category: FittingsStrain Relief
Sub Category: Strain Relief
Type(s): Connector
Connection Type(s): 90 DegreeCord Grip

Used to seal, provide strain relief and terminate portable or flexible cords to metal enclosure or box

  • Suitable for use with S, SO, ST, STO, SJ, SJT,
    SJTO, SJOOW, SOOW, STOOW, SJTOOW and SVO cords
  • 90° Angular
  • Plastic fittings
  • Rubber grommet provides water-tight seal
Model Number
CNA375
CNA377
CNA379
CNA3711
CNA3712
CNA503
CNA505
CNA507
CNA509
CNA5011
CNA5012
CNA5013
CNA5015
CNA5017
CNA757
CNA7510
CNA7512
CNA7514
CNA7516
CNA7518
CNA7519
CNA7520
CNA10014
CNA10016
CNA10018
CNA10019
CNA10020
CNA10021
CNA10022
CNA10023
CNA10024
CNA12521
CNA12523
CNA12524
CNA12525
CNA12526
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cCSAus: 174008

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl)phthalate.
See www.P65Warnings.ca.gov
< Products

90° Cord Grip Non-metallic Connector

Material: Non-Metallic
Category: FittingsStrain Relief
Sub Category: Strain Relief
Type(s): Connector
Connection Type(s): 90 DegreeCord Grip
Feature(s): with Mesh

Used to seal, provide strain relief and terminate portable or flexible cords to metal enclosure or box

  • Suitable for use with S, SO, ST, STO, SJ, SJT, SJTO, SJOOW, SOOW, STOOW, SJTOOW and SVO cords
  • 90° Angular
  • Plastic fittings with stainless steel single/double weave mesh
  • Rubber grommet provides water-tight seal
Model Number
CNA507M
CNA509M
CNA5011M
CNA5012M
CNA5013M
CNA5015M
CNA5017M
CNA7510M
CNA7512M
CNA7514M
CNA7516M
CNA7518M
CNA7519M
CNA7520M
CNA10018M
CNA10019M
CNA10020M
CNA10021M
CNA10023M
ABCVolume
ABCVolume
ABCVolume
cCSAus: 174008

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Di(2-ethylhexyl)phthalate.
See www.P65Warnings.ca.gov
< Products

Combination Conduit Body – Type LB

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: EMTRigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeCombinationSet ScrewThreaded
Feature(s): Type LB

Used with threaded rigid conduit, IMC or EMT for providing access to the interior of a conduit system for pulling, splicing, inspection, and maintenance

  • Assembled with slotted / Robertson combination screws
  • Assembled with rubber gasket and stamped cover
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
CLBC050AN
CLBC075AN
CLBC100AN
CLBC125AN
CLBC150AN
CLBC200AN
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
CSA: LR57925

65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

EMT-to-Flex Coupling

Material: Zinc Die-Cast
Category: Fittings
Sub Category: EMTFlex
Type(s): Coupling
Connection Type(s): Set ScrewSqueeze
Feature(s): Combination

Combination couplings are used to provide a transition from steel EMT conduit to Flexible Metal Conduit. For dry location applications.

  • Set screw type EMT connection
  • Squeeze type Flex connection
Model Number
CMB050SS
CMB075SS
ABCVolume
0.720.931.53
ABCVolume
0.931.161.91
UL: E210498
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

EMT-to-NM Coupling

Material: Zinc Die-Cast
Category: Fittings
Sub Category: EMTNMSE
Type(s): Coupling
Connection Type(s): ClampSet Screw
Feature(s): Combination

Combination couplings are used to provide a transition from steel EMT conduit to NM cable. For dry location applications.

  • Set screw type EMT connection
  • Clamp type NM connection
Model Number
CMB037SS
ABCVolume
0.720.931.34
UL: E210498
CSA: LR57925

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Ground Clamp for Rigid or EMT Conduit with 360° Swivel Hub

Material: Copper Alloy
Category: Fittings
Sub Category: EMTGroundingRigid
Type(s): Clamp
Connection Type(s): For EMT ConduitFor Rigid Conduitwith Hub
Feature(s): Swivel Hub

Used to connect copper grounding conductor in rigid conduit, IMC, or EMT to steel or copper water pipe, or copper ground rod

  • Integral hub accommodates rigid, IMC or EMT conduit and swivels 360° for easy alignment
  • Cast from high strength, highly conductive copper alloy
  • Swivel hub
  • Zinc plated steel hardware
Model Number
C22JPT
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Ground Clamp for Rigid or EMT Conduit with 360° Swivel Hub

Material: Copper Alloy
Category: Fittings
Sub Category: EMTGroundingRigid
Type(s): Clamp
Connection Type(s): For EMT ConduitFor Rigid Conduitwith Hub
Feature(s): Swivel Hub

Used to connect copper grounding conductor in rigid conduit, IMC, or EMT to steel or copper water pipe, or copper ground rod

  • Integral hub accommodates rigid, IMC or EMT conduit and swivels 360° for easy alignment
  • Cast from high strength, highly conductive copper alloy
  • Swivel hub
  • Zinc plated steel hardware
Model Number
C4JPT
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Body – Type LB

Material: Aluminum Die-Cast
Category: Fittings
Sub Category: Rigid
Type(s): Conduit Body
Connection Type(s): 90 DegreeThreaded
Feature(s): Type LB

Used with threaded rigid conduit or IMC for providing access to the interior of a conduit system for pulling, splicing, inspection and maintenance

  • Combination conduit bodies also accommodate EMT applications
  • Assembled with slotted / Robertson combination screws
  • Assembled with rubber gasket and stamped cover
  • Cast from high strength corrosion and weather resistant aluminum alloy
Model Number
CLB050AN
CLB075AN
CLB100AN
CLB125AN
CLB150AN
CLB200AN
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
CSA: LR57925

65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Ground Clamp for Armored Wire with 360° Swivel Hub

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Clamp
Connection Type(s): Armored Wirewith Hub
Feature(s): Swivel Hub

Used to connect bare or armored copper wire to steel or copper water pipe

  • Integral clamp securely holds armor
  • Integral clamp swivels 360° for easy alignment
  • Cast from high strength, highly conductive copper alloy
  • Zinc plated steel hardware
Model Number
C22JA
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Ground Clamp for Armored Wire with 360° Swivel Hub

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Clamp
Connection Type(s): Armored Wirewith Hub
Feature(s): Swivel Hub

Used to connect bare or armored copper wire to steel or copper water pipe

  • Integral clamp securely holds armor
  • Integral clamp swivels 360° for easy alignment
  • Cast from high strength, highly conductive copper alloy
  • Zinc plated steel hardware
Model Number
C4JA
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Ground Clamp for Rigid or EMT Conduit with 360° Swivel Hub

Material: Copper Alloy
Category: Fittings
Sub Category: EMTGroundingRigid
Type(s): Clamp
Connection Type(s): For EMT ConduitFor Rigid Conduitwith Hub
Feature(s): Swivel Hub

Used to connect copper grounding conductor in rigid conduit, IMC, or EMT to steel or copper water pipe, or copper ground rod

  • Integral hub accommodates rigid, IMC or EMT conduit and swivels 360° for easy alignment
  • Cast from high strength, highly conductive copper alloy
  • Swivel hub
  • Zinc plated steel hardware
Model Number
C11JPT
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

45° Cord Grip Al Connector

Material: Aluminum Die-Cast
Category: FittingsStrain Relief
Sub Category: Strain Relief
Type(s): Connector
Connection Type(s): 45 DegreeCord Grip
Feature(s): with Mesh

Used to seal, provide strain relief and terminate portable or flexible cords to metal enclosure or box

  • Suitable for use with S, SO, ST, STO, SJ, SJT, SJTO, SJOOW, SOOW, STOOW, SJTOOW and SVO cords
  • 45° Angular
  • Aluminum fittings with stainless steel single/double weave mesh
  • Rubber grommet provides water-tight seal
Model Number
CGY5025M
CGY501M
CGY502M
CGY503M
CGY504M
CGY7525M
CGY751M
CGY752M
CGY753M
CGY754M
CGY755M
CGY1002M
CGY1004M
CGY1005M
CGY1006M
CGY1007M
CGY1256M
CGY1257M
CGY1258M
CGY1259M
CGY12510M
CGY1506M
CGY1507M
CGY1508M
CGY1509M
CGY15010M
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cCSAus: 174008

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Conduit Hanger

Material: Zinc-Plated Steel
Category: Fittings
Sub Category: AccessoriesEMTRigid
Type(s): Conduit Hanger

Conduit hangers are used to secure and suspend EMT and Rigid conduits from overhead supports.

  • Carriage bolt and nut attached
Model Number
CH050
CH075
CH100
CH125
CH125A
CH150
CH200
CH250
CH300
ABCVolume
1.950.760.69
ABCVolume
2.210.760.81
ABCVolume
2.530.870.92
ABCVolume
2.730.870.98
ABCVolume
3.320.961.1
ABCVolume
3.320.961.1
ABCVolume
4.060.961.12
ABCVolume
4.831.181.26
ABCVolume
5.311.181.26
cULus: E229278

Standards: UL 2239, CSA C22.2 No. 18.4-15
< Products

Ground Clamp for Armored Wire with 360° Swivel Hub

Material: Copper Alloy
Category: Fittings
Sub Category: Grounding
Type(s): Clamp
Connection Type(s): Armored Wirewith Hub
Feature(s): Swivel Hub

Used to connect bare or armored copper wire to steel or copper water pipe

  • Integral clamp securely holds armor
  • Integral clamp swivels 360° for easy alignment
  • Cast from high strength, highly conductive copper alloy
  • Zinc plated steel hardware
Model Number
C11JA
ABCVolume
UL: E88878
CSA: LR57925

Standards: UL 467, CSA C22.2 No. 41
Other: NEC Article 250
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Cord Grip Connector

Material: Zinc Die-Cast
Category: FittingsStrain Relief
Sub Category: Strain Relief
Type(s): Connector
Connection Type(s): Cord GripStraight

Strain relief cord grip connectors are used to connect S, SO, ST, SJ, SJO and SJT cord to an outlet box or metal enclosure.

  • Water-tight when used in conjunction with a sealing locknut (not included)
Model Number
CGC0501
CGC0502
CGC0503
CGC0751
CGC0752
CGC0753
ABCVolume
1.190.50.39
ABCVolume
ABCVolume
1.290.780.41
UL: E121487
CSA: 174008

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov
< Products

Cord Grip Straight Connector

Material: Aluminum Die-Cast
Category: FittingsStrain Relief
Sub Category: Strain Relief
Type(s): Connector
Connection Type(s): Cord GripStraight
Feature(s): with Mesh

Used to seal, provide strain relief and terminate portable or flexible cords to metal enclosure or box

  • Suitable for use with S, SO, ST, STO, SJ, SJT, SJTO, SJOOW, SOOW, STOOW, SJTOOW and SVO cords
  • Aluminum fittings with stainless steel single/double weave mesh
  • Rubber grommet provides water-tight seal
  • Straight female connector
Model Number
CGS3725FM
CGS3726FM
CGS3727FM
CGS3728FM
CGS5025FM
CGS501FM
CGS502FM
CGS504FM
CGS751FM
CGS752FM
CGS754FM
CGS755FM
CGS1002FM
CGS1004FM
CGS1256FM
CGS1257FM
CGS1258FM
CGS1506FM
CGS1507FM
CGS1508FM
CGS1509FM
CGS15010FM
CGS20010FM
CGS20012FM
CGS20013FM
CGS20014FM
CGS20015FM
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
ABCVolume
cCSAus: 174008

Standards: UL 514B, CSA C22.2 No. 18.3-12
65!
WARNING:
Risk of cancer and reproductive harm from exposure to Lead.
See www.P65Warnings.ca.gov